RotoFlex Pump Repair Kit
309793 A
3
Reassembly
Reinstall RotoFlex Pump hose on plate. 
1.
Kink hose as shown, 
making sure dots 
located on hose fitting 
face each other. 
2.
Slide hose onto plate 
as shown below, mak-
ing sure plate slides 
into slot between hex 
fitting on end of hose. 
3.
Align dots located on hose fitting, making sure they 
are facing each other at all times to ensure the hose 
does not twist during reinstallation.
4.
Reposition plate, aligning hex fittings with enclosure 
openings. 
5.
Remove wood block support under motor.
6.
Tighten bolt. As bolt is tightened the plate will snug 
back into place. 
7.
Replace shroud (6 bolts).
8.
Replace hopper.
9.
Break in new pump by running dry or with warm 
water for 3-5 minutes.
ti3127a
DOTS
ti3125a
ti3084a