Installation, cont’d
MGP 464 • Installation
2-4
PRELIMINAR
Y
Installing or Replacing Button Labels
The button caps are pre-labeled for your convenience 
by default.  However, you can replace them with button 
labels that you create, using the Button-Label Generator 
or other button label software.
The button assembly consists of a clear lens cap, the 
button label, and a white diffuser.  (See the illustrations 
at right and below.)  Remove the button assembly from 
the MGP as follows:
1.
 
Make any desired button labels and cut them out.
2
Remove the button assembly by inserting a small, 
flat-bladed screwdriver, such as an Extron Tweeker, 
between the button’s base and the diffuser to 
gently pry the button assembly off the button 
plunger, as shown in the drawing at right.
3
Locate the small corner notch on the lens cap, and slide the screwdriver 
between the lens cap and the diffuser.  (See 
c
 in the illustration below.)
4
Using a rotating motion of the screwdriver, carefully pry the two pieces apart.  
(See 
d
 in the illustration below.)
        
3
4
TEXT 
Separating the two- 
piece button here at 
the corner. 
Pry the two 
pieces apart. 
Diffuser 
Plunger 
Base 
Button Label 
Clear Lens 
Notch 
          
Replacing a button label
5
Lift out the transparent square label that you want to replace, being careful 
not to damage the circuits beneath it.  You may need to use the small 
screwdriver to gently pry the label out.  
6
Insert one of the new labels you created in step 1 into the clear button cap, 
align the white backing plate with the cap, and firmly snap it into place.
7
Gently, but firmly, press the reassembled button into place on the MGP front 
panel.
8
Repeat steps 1 through 7 as needed to relabel other buttons.
Pry the button 
from the base. 
 
 
 
 
   
   
2