Input Configuration submenu
Horizontal Knob Adjustment Vertical Knob Adjustment
Pixel phase 4
The point at which pixels are 
sampled for window 4.  (The values 
cannot be changed for DVI, YUVi, 
S-video, or composite video inputs.)
Select input #1, 2, 3, or 4 for 
window 4.
Increase or decrease the 
displayed value to move the pixel 
sampling point for window 4 to 
an optimal sampling point that 
ensures output clarity.  The range 
of settings is 0-31; default is 16.
Total pixels
The width in pixels of the total 
video display area.  (The values 
cannot be changed for DVI, YUVi, 
S-video, or composite video inputs.)
Select input #1, 2, 3, or 4.
Increase or decrease the width 
in pixels of the total video 
display area of the selected 
input.  Default is marked with an 
asterisk (*).
Active pixels
The width in pixels of the active 
video area
Select input #1, 2, 3, or 4.
Increase or decrease the width 
in pixels of the active video area 
of the selected input.  Default is 
marked with an asterisk (*).
Active lines
The height in lines of the active 
video area
Select input #1, 2, 3, or 4.
Increase or decrease the height 
in lines of the active video area 
of the selected input.  Default is 
marked with an asterisk (*).
Output Configuration menu
The Output Configuration menu allows you to set output resolution, refresh rate, 
output signal type, and sync polarity.  The following flow diagram shows the 
submenus of the Output Configuration menu, and the adjustments that can be 
made from them.
                     
Output 
Configuration 
Next
Resol 
    1024 x 768
Refresh           @60 Hz
Output Type 
RGBHV 
Sync Polarity
H –    V –
Next
Next
Next
Input 
Configuration 
Menu
  Resolution           Refresh rate
 
See the table on the next page for 
available combinations of 
resolutions and refresh rates.
 
Default: 1024 x 768 @60 Hz 
Video signal types
•  RGBHV (default) 
•  RGBS
•  RGsB
•  YUV Bi-Lvl (Current NTSC standard)
•  YUV TriLvl (Current HDTV standard)
Polarity combinations
•  H 
 
 (default)
•  H 
 
V +
•  H + 
•  H + 
V +
•  na*
*Appears when YUV bi-level or tri-level is selected.
Output Configuration menu flow
N
  The menus time out and return to the default cycle after 20 seconds of inactivity;  
however, any selections you made with the Adjust knobs are saved and remain in 
effect.