Miscellaneous messages
Keyboard Error
Keyboard is not present or the hardware is not responding when the keyboard controller is 
initialized.
Keyboard/Interface Error
Keyboard Controller failure. This may indicate a problem with system hardware.
System Halted
The system has been halted. A reset or power cycle is required to reboot the machine. This message 
appears after a fatal error has been detected.
Understanding sensors and sensor readings
Sensor type codes
The following section lists the sensors supported by the BMC, including type, name, status, and 
current reading. The status and current reading information is for example only.
Sensor type
Sensor name
Sensor status
Current reading
Sys. ACPI Pwr State
ACPI State
Normal
5
Module/Board
System Reset
State Deasserted
0
Fan
SYS FAN 1
Normal operating 
range
2362.39 RPM
Fan
SYS FAN 2
Normal operating 
range
1771.79 RPM
Voltage
System 12V
Normal operating 
range
12.04 Volts
Voltage
System 5V
Normal operating 
range
5.0652 Volts
Voltage
System 5V STBY
Normal operating 
range
4.9848 Volts
Voltage
System 3.3V
Normal operating 
range
3.4026 Volts
Voltage
VTT CPU
Normal operating 
range
1.1931 Volts
Voltage
VCORE 0
Normal operating 
range
1.2901 Volts
Voltage
VCORE 1
Normal operating 
range
1.2901 Volts
Voltage
VTT MEM
Normal operating 
range
0.8924 Volts
Voltage
1.5V NB
Normal operating 
range
1.4841 Volts
Voltage
1.9V PHY
Normal operating 
range
1.9206 Volts