Galil COMMAND REFRENNCE DMC-1400 Manual De Usuario

Descargar
Página de 235
76 ● EG  
 
 
 
 
 
   DMC-1400 Series Command Reference 
EG  
 
FUNCTION
ECAM go (engage) 
DESCRIPTION: 
The EG command engages an ECAM operation at a specified position of the master encoder.  
If a value is specified outside of the master’s range, the slave will engage immediately.  
Once a slave motor is engaged, its position is redefined to fit within the cycle. 
ARGUMENTS: EG n 
where  
n is the master position at which the slave axis must be engaged. 
“?” returns 1 if specified axis is engaged and 0 if disengaged 
USAGE
While Moving 
Yes 
Default Value 
 
 In a Program 
Yes 
Default Format   
Command Line 
Yes 
 
 
Can be Interrogated 
No 
 
 
Used as an Operand 
Yes 
  
  
Controller Usage                ALL  
OPERAND USAGE
_EG contains ECAM status .  0 = axis is not engaged, 1 = axis is engaged.   
RELATED COMMANDS: 
Enable Ecam 
Ecam quit 
EXAMPLES: 
EG 700 
Engages axes at master position 700. 
MG_EG 
Return the status of the axis, 1 if engaged 
 
NOTE:  
This command is not a trippoint.  This command will not hold the execution of the program flow.  If the 
execution needs to be held until master position is reached, use MF or MR command