M51A Option Overview  
DLM 600W Series 
1.3 Specifications 
1.3.1 
1.3.2 
Electrical 
Specifications 
 
Remote Voltage Programming Accuracy, 0-5/10V Inputs: 
 
Output Voltage: 0.5% of Vmax 
 
Output Current: 0.75% of Imax 
 
OVP: 1.0% of 1.1 X Vmax 
 
Remote 4-20mA Programming Accuracy: 
 
Output Voltage: 0.75% of Vmax 
 
Output Current: 1.0% of Imax 
 
 
Supplemental 
Characteristics 
 
Remote Resistance Programming Accuracy, 0-5kΩ Input: 
 
Output Voltage: 1.0% of Vmax 
 
Output Current: 1.5% of Imax 
 
OVP: 1.5% of 1.1 X Vmax 
 
Remote Monitor Accuracy: 
 
Output Voltage, 0-5/10V ranges: 0.5% of Vmax 
 
Output Voltage, 4-20mA: 0.75% of Vmax 
 
Output Current, 0-5/10V ranges: 0.75% of Imax 
 
Output Current, 4-20mA: 1.0% of Imax 
 
 
 