Furuno Power Supply M51A Manual De Usuario

Descargar
Página de 22
Isolated Remote Analog Interface Operation 
DLM 600W Series  
2-4 
M51A Option 
2.3  Isolated Analog Interface Connector 
The ISOLATED ANALOG INTERFACE connector is a 25-position female  
Subminiature-D type. 
 
Pin Function 
1 ANALOG-CONTROL 
input 
Return for 0-5/10V monitor outputs and EXTERNAL-OFF 
OVP programming input 
Voltage monitor output, 4-20mA 
VOLTAGE-MODE status output 
Return for 4-20mA monitor outputs, Auxiliary 5VDC, and digital I/O 
Current monitor output, 0-5/10V 
1.25VDC output for 4-20mA voltage programming signal 
Voltage programming input 
10 
Current programming input 
11 
1.25VDC output for 4-20mA current programming signal 
12 
Return for 0-5/10V or resistance programming signals 
13 
Return for 4-20mA current programming signal 
14 EXTERNAL-OFF 
input 
15 
Auxiliary 5VDC output (+) 
16 
OVP resistance programming output, 1mA source 
17 
OVP status output 
18 
FAULT status output 
19 
Voltage monitor output, 0-5/10V 
20 
1.25V input for 4-20mA voltage programming signal 
21 
Voltage resistance programming output, 1mA source 
22 
Current resistance programming output, 1mA source 
23 
1.25V input for 4-20mA current programming signal 
24 
Current monitor output, 4-20mA 
25 
Return for 4-20mA voltage programming 
 
Table 2–2.  ISOLATED ANALOG INTERFACE Connector Pinout 
 
 
CAUTION 
The signals of the ISOLATED ANALOG INTERFACE have an internal 
connection to chassis ground. Damage could result if the voltage from 
signal returns, Pin-2, 6, 12, 13, and 25, to chassis ground exceeds 
15VDC.