SK-96370-144PMC-GDC User Guide 
Chapter 3 Jumpers and Switches 
FMEMCU-UG-960014-10 
- 18 - 
© Fujitsu Microelectronics Europe GmbH 
3.6 Reset 
Generation 
(JP: 33, 41, 46, 47, 48) 
In addition to the internal Power-On reset, the microcontroller can be reset by an external 
reset circuit (Voltage Monitor) and also by a RS232 interface. Refer to the chapter ‘LIN / 
UART Connectors (X5 or X9)’ for DTR / RTS selection. 
 
JP33     Selects X5 or X9 as reset source. 
JP41 
The signal on the DTR/RTS line can be negated with this jumper.  
 
Remove the jumper in order to disable the RS232 reset circuit. 
JP46 
Selects the mode of the reset button SW6. 
JP47 
A voltage supply monitor allows monitoring of 1V8 or 2V5 power supply. 
JP48 
Open this jumper if no external Reset shall be generated.  
 
In this case only the internal reset is active (e.g.: power-on). 
 
Jumper 
Setting 
Description 
1-2 
X5 (UART0) is used to generate Reset 
JP33 
(UART RESET) 
2-3 
X9 (UART2) is used to generate Reset 
1-2 
No polarity inversion for the DTR/RTS signal 
JP41 
(DTR / DTRx) 
2-3 
Polarity inversion for the DTR/RTS signal 
1-2 
Reset is applied immediately when SW6 is pressed 
JP46 
(Reset imm./delayed) 
2-3 
Reset is applied when SW6 is pressed > 2sec 
1-2 
The voltage supply monitor observes 1V8 
JP47 
(Monitor 1V8 / 2V5) 
2-3 
The voltage supply monitor observes 2V5 
Closed 
External reset generation is active 
JP48 
(RST MCU) 
Open No 
external 
reset 
generation 
Table 3-5: Reset Connection 
 
By default, the external reset is enabled and set to immediate reset while the reset by UART 
is disabled. 
 
Note:
While a reset signal is asserted the red Reset-LED LD13 is lit.  
During normal operation, this LED should be off!  
If JP41 (DTR/DTRx) is set, the UART RESET jumper (JP33) and the according DTR/RTS 
(JP23 and JP38) jumper have to be set, too. 
If the reset LED is steadily on, check the power supply input voltage and the settings for the 
reset-generation by UART.