SECTION IV 
PRE-INSTALLATION 
 
UNPACKING 
INSPECT SHIPMENT carefully for any signs of damage.  If damage is noted, do not install the product.  Contact 
the shipper or manufacturer listed on the rating plate.  All equipment is carefully manufactured, inspected, and 
packed.  Our responsibility ceases upon delivery of the packaged water heater to the carrier in good condition. 
NOTE:
 Any claims for damage or shortage in shipment must be filed immediately against the carrier by the 
consignee.   
 
This water heater MUST be installed indoors out of the wind and weather. 
Component Location 
 
 
Clearance from Combustible Materials
Top Sides Front Rear 
0” 0” 0” 0” 
Table 5 – Combustible Material Clearances 
 
 
Recommended Service Clearances 
Non-Piping 
Side 
Front  
(Heat Exchanger) 
 
Rear 
T & P Relief 
Valve Side 
4” 16” 
0” 
6” 
Table 6 – Service Clearances 
 
 
 
 
1.  Heater 
Location – For fastest delivery of hot water, place the solar water heater closest to the points of use. 
 
Additional Recommended Components 
1.  Shut-off Valves – Allows isolation of water heater from domestic water system and/or solar system 
during service. 
2.  Unions – Allows water heater movement during service if adequate clearance cannot be provided. 
3.  Thermal Expansion Tank – If the water heater is installed in a closed water supply system, such as 
one having a back-flow preventer in the cold water line, provide thermal expansion control.  Contact 
the water supplier or local plumbing inspector for additional information.   
 
MOVE THE WATER HEATER TO A PERMANENT POSITION
 BY SLIDING OR WALKING. 
 
 
 
CAUTION
 
This water heater must be located in an area where leakage of the tank, water line connections, or the temperature 
and pressure relief valve will not result in damage to the area adjacent to the water heater/storage unit or to lower 
floors of the structure.  When such locations cannot be avoided, a suitable drain pan must be installed under the 
water heater/storage unit.  The drain pan depth must be suitable for draining and collecting water.  The drain pan 
can be purchased from your plumbing professional.  The drain pan must be piped to an adequate drain.  The piping 
must be at least ¾ inch in diameter and pitched for proper drainage.  
 
CAUTION
 
Do not drop water heater.  Do not bump water heater jacket against floor.