Bradford-White Corp Solar Water Heater Manual De Usuario

Descargar
Página de 28
23 
 
Maintenance continued- 
   
4. 
Sediment (Annual, but harsh water quality may dictate more frequent service) - Depending on water 
conditions, a varying amount of sediment may collect in the tank.  Levels requiring service are indicated by a 
small temperature difference in the supply and return lines (See also “Scale” below).  Repeated flushing usually 
clears such material.  As a preventive measure, water should be drawn from the tank at the drain valve until it 
runs clear. 
 
5. 
Scale (Annual) - Hard water may cause scale to build-up on the outside of the heat exchanger coil.  A water 
softener will prevent this problem (See also “Sediment” above).  Symptoms would be reduced recovery 
capacity or reduced temperature differential between solar collector supply and return lines.  Repeated flushing 
should resolve the problem. 
 
6. 
Solar Controller -The solar controller manufacturer may have a recommended maintenance procedure.  Refer 
to the installation and operation manual that was received with the solar controller. 
 
7. 
Solar Collector Panels - The solar collector panel manufacturer may have a recommended maintenance 
procedure.  Refer to the installation and operation manual that was received with the solar collector panels.