Bradford-White Corp Water Heater C(S Manual De Usuario

Descargar
Página de 28
Troubleshooting Chart
Symptom
Probable Cause
Corrective Action
Pilot will not light
1. No incoming gas or too low gas
    pressure.
2. Gas control knob set to wrong position.
3. Pilot light button not being fully
    depressed when attempting to light pilot.
4. Pilot orifice or pilot tube is obstructed or
    kinked.
1. Poor thermocouple connection at
    gas control.
2. Thermocouple not fully engaged in pilot
    assembly bracket.
3. Pilot flame is not fully enveloping the
    thermocouple “hot” junction.
4. Weak or defective thermocouple.
5. Open ECO on gas control.
6. Defective magnet in gas control.
Pilot will not
stay lit
when button is released
Pilot will light, but the
main burner will not
come on
1. Gas Control set too low for desired water
    temperature.
2. Gas Control temperature is satisfied.
3. Insufficient gas supply or low gas
    pressure.
4. Gas Control has wide differential or is out
    of calibration.
Pilot goes out
periodically (after
heating cycles, once a
day, once a week etc.)
1. Insufficient combustion air supply.
2. Incorrect, clogged vent system/ vent
    terminal or location.
3. Inconsistent gas supply or gas pressure.
Not enough hot water
1. Gas Control set too low for desired water
    temperature.
2. Cold inlet water temperature is very cold.
3. High demand periods.
4. Incorrectly sized water heater for
    application.
5. Gas Control is out of calibration/not
    functioning.
6. Out of spec dip tube is diluting hot water
    with cold water.
7. Integrated mixing device is set too low for
    desired water temperature.
1. Turn on gas supply and/or check line
    pressure.
2. Review lighting instruction. Set
    gas control to correct position.
3. Review lighting instruction. Fully depress
    pilot lighting button.
4. Clean, repair or replace.
1. Check connection at gas control.
    Proper tightness should be finger tight plus
    ¼ turn.
2. Inspect thermocouple to ensure that it is
    fully engaged into pilot bracket.
3. Adjust tip of thermocouple to be fully
    engulfed by pilot flame.
4. Check thermocouple and replace if
    necessary.
5. Check ECO continuity and replace
    gas control if necessary.
6. Check magnet operation and replace
    gas control if necessary.
1. Adjust temperature dial on gas control.
2. Check temperature dial setting on
     gas control.
3. Check gas supply and line pressure.
4. Check gas control
    for proper operation, replace if
    necessary.
1. Verify adequate combustion air is available
    to the unit. Check and clear Jacket slot
    openings of any dirt, dust, restrictions or
    other obstructions.
2. Check venting for proper sizing and proper
    operation
3. Check gas supply and line pressure.
1. Check dial on gas control.
2.Extremely cold water going into the water
   heater will decrease the amount of hot
   water produced. It may be necessary to
   temper incoming water supply.
3. Adjust high demand usage.
4. Contact Plumbing professional.
5. Check gas control
    for proper operation, replace if
    necessary.
6. Inspect dip tube and replace if necessary.
7. Reset device using the procedure
    in the instructions included with the device.
Service
Procedure
1. See Service Procedure
    AG-III, Page 12.
4. See Service Procedure
    AG-II, Page 9.
4. See Service Procedure
    AG-I, Page 6
5. See Service Procedure
    AG-III, Page 12
6. See Service Procedure
    AG-III, Page 12
2. See Installation &
    operation manual.
3. See Service Procedure
    AG-III, Page 12
4. See Service Procedure
    AG-III, Page 12
3. See Service Procedure
    AG-III, Page 12
5. See Service Procedure
    AG-III, Page 12
6. See Service Procedure
    AG-V, Page 23
Page 3
For Models Using White Rodgers or Robertshaw Thermostat