troubleshooting (cont.)
iMpOrtant!
Be certain to shut off the plasma cutter, and disconnect it from power and air before adjusting, cleaning, 
or repairing the unit. a technician should discharge all capacitors before performing any internal procedures.
if the steps above do not solve the problem or if the repairs involved are too 
complex, contact a qualified technician.
current set too high;  
cut at lowest setting possible 
for the metal being cut.
FaSt cuttinG tip Wear Or eXceSSiVe SLaG FOrMatiOn
take into account the thickness 
and type of metal to be cut 
before starting. thinner materials 
require lower amp settings.
prOBLeMS 
reDuceD
Disassemble and inspect 
torch according to 
number 2 on page 10.
replace worn components, then 
reassemble torch tightly according 
to number 2 on page 10.
tOrcH in GOOD 
cOnDitiOn
DaMaGeD 
cOMpOnentS FOunD
air supply pressure may be inadequate:
a.  Verify that the compressor is 
delivering 4.5 cFM @ 80 pSi.
b.  Set cutter's air pressure regulator between 60 - 80 pSi.
additional factors:
a. Maintain a 1/16" distance from workpiece at all times.
b. Move torch at proper rate. Maximum cutting speeds:
   3/8" Mild Steel @ 10 ipM (rated)
   5/8" Mild Steel @ 5 ipM (Severence)
c. compare workpiece thickness 
to Maximum cutting thickness on page 5.
these two problems have similar causes 
and will often appear simultaneously.
the same diagnostic procedures 
and remedies apply to both.
prOBLeMS perSiSt at 
LOWeSt practicaL SettinG