For technical questions, please call 1-888-866-5797.
ITEM 62204 
        
Sa
Fety
Opera
ti
O
n
Maintenance
Setup
air Supply
tO preVent SeriOuS inJury anD DeatH FrOM eXpLOSiOn: 
use only clean, dry, regulated, oil-free, compressed air or nitrogen gas with this plasma cutter.  
Do not use oxygen, acetylene, carbon dioxide, combustible gases,  
or any other bottled gas as a power source for this plasma cutter.
1� 
Use a compressor that is capable of 
supplying 4�5 CFM @ 80 PSI�
2� 
Incorporate a filter, regulator with pressure gauge, 
dryer, in‑line shutoff valve, and quick coupler for 
best service� 
an in-line shutoff ball valve is an 
important safety device because it controls 
the air supply even if the air hose is ruptured. 
the shutoff valve should be a ball valve 
because it can be closed quickly.
note: in humid locations, multiple dryers may need 
to be incorporated to keep the air dry. MOiSture 
in air SuppLy May cauSe SHOrteneD 
cOMpOnent LiFe anD pOOr cut QuaLity. 
note: Do not use an oiler system with this 
plasma cutter. the oil will mix with the air 
being propelled, causing poor results.
3� 
Attach an air hose to the compressor’s air outlet� 
Connect the air hose to the Air Inlet on the back 
of the Plasma Cutter� Other components, such 
as a coupler plug and quick coupler, will make 
operation more efficient, but are not required�
note: Air flow, and therefore Plasma Cutter 
performance, can be hindered by undersized air 
supply components�  
The air hose must be long enough to reach 
the work area with enough extra length to 
allow free movement while working�
Setting compressor's air pressure
1� 
Set the Plasma Cutter’s 
power 
Switch to the OFF position� 
2� 
Turn on the air compressor according to 
the manufacturer’s directions and allow it 
to build up pressure until it cycles off�
3� 
Set the air compressor’s output air 
pressure regulator between 
90 - 120 
pSi� Adjust the pressure gradually, while 
observing the air pressure gauge�
4� 
Inspect the air connections for leaks� 
Repair any leaks found�
Setting plasma cutter's air pressure
1� 
Plug in the Plasm Cutter, set the 
power Switch 
to the 
On position and set the air Switch to 
Set air� There will be constant air flow�
2� 
Pull up on the 
air pressure regulator 
and set between 
60 - 80 pSi, as observed 
on the 
air pressure Gauge.
3� 
teSt air FLOW:
WarninG! Make sure torch and 
cutting tip are completely cool.
a�  Hold Air Flowmeter firmly against end 
of Cutting Tip, pointing Torch and Air 
Flowmeter straight up� 
See Figure B.
b�  The ball should float in the marked area on the 
meter� If not, adjust air pressure, as needed, 
while observing the Air Pressure Gauge�
4� 
iMpOrtant! After testing, set air Switch 
to cut to allow normal operation� 
MAX
MIN
torch
air 
Flowmeter
Ball
Figure B