Installation and Replacement 
3-11
Configuring the Serial Interface
V.35/V.36, and X.21/
V.11 Interface 
Types
Use this procedure to set the Interface Options parameter for V.35, V.36, and 
X.21/V.11 interface types:
Step
Action
Result/Description
1
From the Control Terminal Port 
Main menu, select Configure -> 
Port
.
The Port record appears.
2
In the Port Number parameter, type 
3, then press ENTER.
Port 3 is selected.
3
In the Port Type parameter, type 
FRI, then press ENTER
This defines Port 3 type as FRI.
4
In the Interface Type parameter, type 
one of these interfaces: V.35, V.36, 
X.21 
and then press ENTER.
The interface is set to the selected 
type.
5
In the Interface Options parameter, 
type a ?, and then press ENTER.
The Range and Default appears:
Range = NONE, XOVER
Default = NONE
Specify the cable type:
NONE - V35/V.36/X.21 DCE 
with straight through cable
XOVER - V35/V.36/X.21 DCE 
with crossover adapter cable
6
Select either NONE for straight 
DCE mode, or XOVER when using 
the DTE crossover adapter cable.
When NONE is selected, the serial 
interface is in straight DCE mode. 
When XOVER is selected, the 
serial interface is in DCE Mode 
using the adapter cable.