Siemens TV Converter Box 611 Manual De Usuario

Descargar
Página de 324
 
Interfaces 
 
8.2 Electrical connections 
 
The cables for the power connection are brought out at the front of the stator (B side). The 
open cable ends must be connected in a terminal box, which must be provided by the 
machine manufacturer. Sufficient installation space must be provided in the axes 
construction. Standard MOTION–CONNECT cables, which are available with the standard 
range of accessories for the drive system, can be used from this EMC-compliant terminal 
box (minimum degree of protection: IP54). 
8.2.1 
Power connection 
Connection assignment 
Table 8- 4 
Power connection for torque motor 
Converter 
Torque motor/stator 
U2 
V2 
W2 
For information on the power connection, refer also to the system integration images 
contained in the chapter titled "System requirements". The rotor turns clockwise if the torque 
motor is connected in phase sequence U, V, W. Also refer to "Direction of rotation" in 
Chapter "Technical features".  
8.2.2 
Signal connection 
No direct connection of the temperature monitoring circuits! 
 
DANGER 
 
The temperature monitoring circuits represent a risk of electrical shock! 
A direct connection of the temperature monitoring circuits Temp-F and Temp-S at the 
encoder connectors X411/X412 of the SIMODRIVE control module does not satisfy the 
regulations for protective separation in accordance with EN 61800-5-1. A connection of the 
temperature monitoring circuits Temp-F and Temp-S at the encoder connectors X411/X412 
of the SIMODRIVE control module is therefore not permitted without the use of a suitable 
protection module (e.g. SME9x). 
 
Temperature sensor connection via SME9x 
A connector is used to connect the signal cable to the SME9x (Sensor Module External), 
whose output is connected at the converter. For more information, see the system 
integration images contained in the chapter titled "System requirements", as well as the 
connection overview below.  
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7 
145