• The MadiXtreme Properties window is divided into three sections. The top section (Clock) allows you to define the clock
settings you require for your studio. The middle section (Format) controls the audio configuration. The bottom section
(Status) shows whether the MadiXtreme is correctly synchronized to a clock signal and whether the MADI inputs are
locked to a valid incoming MADI signal.
Clock Settings
Master and Slave option boxes
When multiple MadiXtremes are used in the same host computer, they must all be locked to the same clock signal. One
of the cards must be set as the ‘master device’, the other(s) must be set as ‘slave device(s)’ by ticking the Master or Slave
option box. If a single MadiXtreme is used, only the Master setting can be selected.
Please note that setting a card to Master does NOT mean that the card is used as a ‘clock master’. It simply means
that it is the ‘Soundscape Master Device’, and that other Soundscape cards must receive its clock reference signal
(directly or indirectly), or be clocked from the same source. The ‘Soundscape Master Device’ can itself be clocked
from an external clock source.
The ability to set one SSL audio card as master device, and pre-select a clock source for each card according to its
master/slave device status, means that whenever a new card is set to master, the previous master automatically switches
to slave and to the corresponding pre-selected clock source. There is no need to change the settings of each card
manually, it is all done automatically according to your clock pre-selections.
Also, when used as a master device and slaved to an external clock signal, MadiXtreme checks for changes to the sample
rate of that clock signal and changes its own sample rate setting accordingly. These sample rate changes are applied
automatically to the Soundscape slave devices.
Clock Source Selectors
Separate selection menus are provided to select the clock source for the card when used as a Soundscape Master Device
or as a Soundscape Slave Device.
The selection menus provide the following options:
• Internal: If this option is selected, MadiXtreme locks to its own on-board clock generator. It also means that the BNC
connector operates as a WordClock output, suitable to provide a clock reference to the slave devices.
The Internal setting is only available when Master is selected.
• Sync-in Word Clock: If this option is selected, MadiXtreme will lock to a WordClock signal received via its BNC connector,
which will operate as an input.
• MADI-A or MADI-B: If either of these options is selected, MadiXtreme will lock to the MADI clock signal received via
the corresponding MADI input port.
(MADI-B is applicable only to the MadiXtreme 128.)
Page 17
Click to set card as the ‘master device’
Click to set card as a ‘slave device’
Clock source selector (when card is a ‘master device’)