PROGRAM LIMITS  
 
1.  Process Limit1 
2.  Process Limit2 
3.  Setup limt 3 for Rate/Process 
4.  Process  Limit 3 
5.  Setup Limit4 for Process/Deviation 
6.  Process Limit 4 
7.  Timer 1 Limit 
8. Timer 2 Limit 
9. Deadband for limits 
9.   Limits Normally open/close (1 Thru 4) 
10. Limits Latching/Non Latching 
11. Audio Alarm On/Off 
PROGRAM SYSTEM 
 
1. Display Options 
2. Flash Time 
3. Engineering units 
4. Program Setpoint 
5. Remote Tare/Hold 
6. Input Type 
7. Input Range 
 
 
 SCALING 
 
 1. High Scale 
 2. Low Scale 
 3. Offset 
 4. Tare 
 
 
Programming Group Selection: 
 
On entering correct passcode, setup procedure starts. The very first step will let you select one of the three 
groups of  parameters that you can program. Three available groups are:  1) SCALING      2)  PROGRAM 
LIMITS    3)  PROGRAM SYSTEM. Each group will let you program various parameters as shown below: 
 
Push ^v key to move from one programming group to the next. When a desired group is displayed, push 
SETUP key to select it. 
 
SCALING 
 
Decimal point: 
                
Decimal point mode is indicated as ‘dp 9999’ (dp stands for DECIMAL POINT). Push ^v key to program 
decimal point. Each push on the ^v key moves the decimal point to the next position. After 9.999 the display 
will go to 9999. When proper decimal point position has been obtained push SETUP key to go to the next 
mode. 
 
High Scale: 
 
High scale mode is indicated by a brief display of the message ‘HI SCLE’ followed by high scale value. 
The least significant digit (right most digit) will be flashing. The flashing indicates that pushing ^v key will 
increment or decrement that particular digit. Pushing ^v key once and holding it down will increment the 
flashing digit. Releasing the ^v key and pushing it again immediately ( and then holding it in) will start 
decrementing the display. The desired number can be programmed by toggling the ^v key. To move to the 
next significant digit push <NXT> key, and to increment or decrement it, use ^v key. After obtaining a new 
high scale value (or to retain the current one) push SETUP key to get to the next mode. 
 
Low Scale: 
 
Low Scale mode is indicated by the display first flashing ‘LO SCLE’ and then the pre-programmed value 
of low scale. Again, to change the flashing digit value use ^v key. To change any other digit, use <NXT> 
key to make that digit flash and then use ^v key to change its value. After obtaining a new value (or to retain 
the present value) push setup key. This will also get you into the next function.