CTEK Power USA Automobile Battery Charger XS 800 Manual De Usuario

Descargar
Página de 7
BATTERY TYPES 
The following recommendations should only be considered as guidelines. In the event of 
uncertainty always refer to the battery manufacturer’s recommendations.
CTEK XS 800 is suitable for charging all types of 12V lead-acid batteries: open batteries, 
MF, AGM and most GEL-batteries. Battery sizes from 1.2 to 32Ah. The charger can maintain 
batteries up to 100Ah. 
CHARGING
Charging batteries mounted in a vehicle:
1. The power cord should be disconnected before connecting or disconnecting the battery 
leads.
2. Identify the pole that is grounded (attached to the chassis). Ground is normally connected to 
the negative terminal.
3. Charging a negatively grounded battery. Connect the red wire to the positive pole of the 
battery and the black cable to the vehicle’s chassis. Be careful not to connect the black cable in 
the vicinity of a fuel pipe or the battery. 
4. Charging a positively grounded battery. Connect the black wire to the negative pole of the 
battery and the red cable to the vehicle's chassis. Be careful not to connect the red cable in the 
vicinity of a fuel pipe or the battery. 
Charging of a battery not connected to a vehicle:
1. The power cord should be disconnected before connecting or disconnecting the battery 
leads.
2. Connect the red wire to the positive pole of the battery and the black cable to the negative 
pole.
Connecting the provided cables with eyelet terminals:
Make sure that the cable is not being pinched or in contact with warm surfaces or sharp edges. 
When the cable is mounted on the battery, it should not be connected to the charger. Connect 
the eyelet terminals to the battery's poles - the red cable to the positive pole and the black cable 
to the negative pole. After this, the quick contact can be connected.
Reverse Polarity Protection
If the battery cables are connected incorrectly, the reverse polarity protection will make sure that 
the charger and the battery are not damaged. In this case, the red warning lamp 
 will be lit.