CTEK Power USA Network Router CDMA2000 1XRTT Access Point and Router Manual De Usuario

Descargar
Página de 27
Part Number 91-007-02 
 
3
 
2  Connectors, Lights, Switches, and Jumpers 
 
2.1 Switches 
 
Referring to Figure 1, there are two switches on the back of the Series 4100E.  S1 (Reset) causes a hard reset of unit. S2 
(Restore Defaults) is used to completely restore the firmware settings that were included when the product was shipped 
from the factory.To restore factory defaults, the unit must be running. Press the Restore Defaults (inner) switch and hold it 
down for 10 seconds. After 10 seconds, you will see both the green and yellow lights go off. At that time you may either 
press the reset (outer) switch or cycle power on the unit. 
 
 
 
Figure 1 
 
 
2.2 Connectors 
 
Ethernet Connectors 
 
Connectors are found on the front of the Series 4100E SkyRouter. Ethernet ports 1 – 4 are auto polarity sensing and can 
be used with either a standard Ethernet cable or a reverse (cross over) Ethernet cable. 
 
Terminal Block 
 
Connector J1 supports three separate functions, power, relay contact closure detection and the relay driver output 
 
The pin out configuration is as follows: 
 
Pin 1 - Relay in Sense Voltage Source 3.3vdc with over current protection 
Pin 2 - Relay In Sense 
Pin 3 - Relay Out Voltage Source 12vdc @40ma or less 
Pin 4 - Relay Out Control 
Pin 5 - Ground 
Pin 6 - +12VDC 
 
Antenna Connector - Standard SMA type female connector.