5.  MAINTENANCE, TROUBLESHOOTING
11
5.2
Replacing the Fuse
The 2A fuse inside the unit protects it from overcurrent and equipment fault. If the power cannot 
be turned on, have a qualified technician check the fuse. If the fuse has blown, find out the cause 
before replacing it. If it blows again, contact your dealer for advice.
5.3
Troubleshooting
This section provides simple troubleshooting procedures which the user can follow to restore nor-
mal operation. If normal operation cannot be restored, do not attempt to check inside the equip-
ment. There are no user-serviceable parts inside.
Simple troubleshooting procedures
Item
Type
Code No,
Fuse
FGMB 125V 2A PBF
000-157-479-10
Symptom
Possible trouble
Remedy
Power cannot be 
turned on
•  Power at switchboard is turned 
off.
•  Disconnected or damaged 
power cable.
• Blown fuse.
•  Check if power is on at switchboard.
•  Check if power cable is disconnected 
or damaged.
•  Have a qualified technician check the 
fuse.
Data is not received 
from SC-30
•  Signal cable between the SC-
30 and this equipment is dam-
aged or disconnected.
•  SC-30 is no received satellite 
signal.
•  Check if sensor cable is disconnect-
ed or damaged.
•  See the SC-30's operator's manual. 
Data is not received 
at external equip-
ment
•  Disconnected or damaged in-
terconnection cable.
•  Output settings may be incor-
rect.
•  Check if cable is disconnected or 
damaged.
•  Have a qualified technician check the 
settings.
Heading, pitch or roll 
data is not correct
•  Offsets entered in this equip-
ment may be incorrect.
•  Have a qualified technician check the 
settings.