Connect Tech BLUE HEAT/NET SYNC CTIM-00044 Manual De Usuario

Descargar
Página de 76
Connect Tech Blue Heat/Net Sync User Manual 
 
22                                                                                                                                    Revision 0.03 
Set the IP Address Using the Web Configuration Manager  
 
NOTE: If you use the Windows Configuration Manager 
and use Auto Discover to locate your Blue Heat/Net 
Sync on the network, you can right-click and launch the 
Web Configuration Manager from there. 
You only need to use the route add command if you 
choose not to use the Configuration Manager found on 
the CD that accompanied your Blue Heat/Net Sync unit. 
 
From the command prompt of your computer, run: route
 
add A.B.C.0 mask 255.255.255.0 <current 
IP of your host machine>
 
Be sure to replace the .D from the Blue Heat/Net Sync‟s IP with a 
(zero).  Open your browser and put the Blue Heat/Net Sync‟s IP in the address bar (i.e. A.B.C.D
This will open the WCM. Log in (default login is wcm and the default password is password
and assign the static IP or change the IP to 0.0.0.0 if you are using a DHCP assigned IP. 
Set the IP Address Using the Serial Configuration Manager  
Insert your CD into the computer and complete the following steps: 
 
1.  Once your CD has been inserted, the Driver/Software Installation menu should appear. If it 
doesn‟t, double-click on ctisetup.htm.   
 
2.  Click View in the Blue Heat/Net Sync Software section and then Connect in the Serial 
Configuration Manager section. This will launch HyperTerminal that comes with Windows XP. 
 
3.  Unplug the power to the Blue Heat/Net Sync and plug it back in. Light indicators 1 to 4 will 
blink sequentially. This sequential flashing will last for 30 seconds. You must log in during 
this window.
  
 
4.  During this sequential flashing, type the word password into the HyperTerminal window. Be 
careful you do not miss the window of opportunity to enter the password.  
 
5.  You now have access to the Serial Configuration Manager (SCM). An scm> prompt is ready 
to accept commands. If you do not see this prompt, unplug the power and repeat the steps above. 
 
If you wish to set a dynamic IP address enter the following: 
net dhcp=yes 
save 
exit 
 
If you wish to set a static IP address, enter the following, substituting xxx.xxx.xxx.xxx
 
with the 
static IP you wish to assign: 
net mip=xxx.xxx.xxx.xxx 
save 
exit 
 
Close the HyperTerminal. You may now disconnect the DB-25 cable from your PC and connect 
it to any serial device