26                                                                                                                                    Revision 0.03 
 
Save setting changes to non-volatile flash storage 
 
Download a new operating system via TFTP and flash,  
 
 
 
   
(uClinux) and loader/SCM image. 
Command Details 
boot 
Syntax: 
boot [mode=] [file=] [delay=] 
 
Description: 
This command establishes the Blue Heat/Net Sync boot-up mode. For a detailed 
description of the boot-up process of the Blue Heat/Net Sync, see 
 in the Appendix. 
 
Options: 
mode= 
 
A comma-separated list of the following sub-options. Each sub-option is 
 
preceded by either a + or a  to indicate if the sub-option is enabled or disabled. 
 
±flash  Enables or disables the ability to boot from the flash memory. 
±bootp Enables or disables the ability to obtain the boot-up information from a 
Server. 
±tftp Enables or disables the ability to download and boot from a file located on 
a Server. 
 
file= 
This option specifies the default file name used for the boot-up (if TFTP boot is 
enabled) and also the default file name when using the flos command. 
This can be any sequence of characters up to 128 characters in length. (The 
default is BHNuClinux_vvv.gz, where vvv is the current version number of the 
“Operating System image”). 
 
delay= 
This sets the time duration for accessing the SCM application. It can be set from 
2 to 30 seconds, the default is 30. (See the section 
 for more information). 
cfg 
Syntax: 
cfg  [port=] [timeout=] [password=] [prompt=] [file=] 
 
Description: 
Establishes the settings used by the SCM application to  
 
 
 
 
modify its behavior. 
 
Options: 
port= 
 
 
Specifies the port number to scan for a password to gain entry in the SCM. 
 
 
N = Scan just port N (N=1 to the number of ports on the unit). 
 
 
255 = Scan all ports on the unit (default unless unit has programmable line  
 
 
interfaces). 
 
timeout= 
Specifies the time duration allowed for a TCM (via telnet) session to be idle (no 
activity) before the session is terminated. 
0 to 1092 minutes 
(default = 5) 
Note: A setting of zero allows infinite timeout. 
 
NOTE: The TCM function is currently not available with this 
product.