INSTALLATION 
 
Page 2-1
 
CHAPTER 2 
INSTALLATION
 
2.1
INTRODUCTION
 
The Cabletron Systems THN-MIM is designed for quick and easy 
installation into an MMAC. No special skills or tools are required to 
install this module.
 
2.2
NETWORK DESIGN GUIDELINES
 
The following network design guidelines must be followed when 
connecting segments to the THN-MIM. If not, unsatisfactory network 
performance may result.
 
2.2.1
Thin-net Segments
 
This applies to the THN-MIM only.  For the THN-MIM7593, see 
section 2.2.2.
50 ohm RG-58A/U type coaxial cable must be used when making up 
a thin-net cable segment. A 50 ohm terminator must be connected 
to the far end of the thin-net segment.
A maximum of 30 connections may be made to a thin-net cable 
segment. These connections must be at least 0.5 meter apart.
For safety, only one end of a thin-net segment should be connected 
to earth ground. Connection to earth ground at more than one point 
on the segment may allow for the occurrence of dangerous ground 
currents. The BNC ports of the THN-MIM are connected to earth 
ground. This eliminates the need of grounding the thin-net 
segments connected to the module.
Connections on a thin-net cable segment to host systems or 
transceivers are made by BNC tee connectors. The male end of the 
BNC tee connector is used to connect directly to the host or to the 
transceiver. The female ends of the tee connector must be 
connected to another part of the segment or to a terminator.