CAT Titan 250 Manual De Usuario

Descargar
Página de 81
Turbomachinery Package Specification 
Titan 
250 Generator Set 
•  Fuel pilot control valve 
•  Fuel pilot manifold 
•  Inlet gas filter/coalescer loose shipped for field installation 
Component Operation 
The gas fuel pressure supplied to the turbine skid must meet minimum and maximum 
pressure and flow requirements. If the gas fuel pressure is too high or too low, the control 
system will prevent turbine operation. Pneumatically actuated primary and secondary gas 
fuel shutoff valves are controlled using pilot air pressure. For each valve, pilot air 
pressure is admitted to and exhausted from a pneumatic actuator through a solenoid 
valve. Fail-safe operation ensures both valves will close in case pilot air pressure is lost. 
The gas fuel control valves and the SoLoNOx  fuel pilot control valve, are powered by 
integrated DC motor-driven actuators. Integrated actuator electronics provide precise 
closed-loop valve control based on position command inputs versus position feedback 
outputs. The three valves are fast acting and provide fuel metering for light-off, 
acceleration, full load, and load transient conditions. Fail-safe operation ensures both 
valves will close in case the command signal or control power is lost. During the start 
sequence prior to ignition, the control system will verify gas pressure and perform a gas 
valve check to verify proper operation of all gas fuel valves. 
 
Table 5. 
Fuel System Specifications 
Gas Fuel System 
Acceptable Gas Fuels See Note (a) 
Natural Gas 
Propane 
Butane 
Fuel Quality 
Refer to Solar’s Engineering Specification ES 9-98 
Compliance 
National Association of Corrosion Engineers 
(NACE) Compliant 
Minimum/Maximum Gas Fuel Supply Pressure 
2240 to 3447 kPag (325 to 500 psig), See Note (b) 
Minimum Flow Rate 
3513 to 5480 kg/hr (7746 to 12086 lbm/hr), See 
Note (b)
 
Minimum/Maximum Fuel Supply Temperature 
-40 to 93
°C (-40 to 200°F), See Note (c) 
Primary Gas Fuel Shutoff Valve 
Pneumatically Actuated Spring-Closed Ball Valve 
Secondary Gas Fuel Shutoff Valve 
Pneumatically Actuated Vane Type Valve 
Gas Fuel Control Valve and SoLoNOx Fuel Pilot 
Control Valve 
Actuator Valve 
Actuator Voltage 
120 VDC 
Valve Discrete Signals 
0 to 24 VDC 
Valve Analog Signals 
4 to 20 mA 
Maximum Operating Pressure 
4137 kPag (600 psig) 
Maximum Operating Temperature 
93°C (200°F) 
Response Time 
Less Than 100 msec From 10-to-90% Stroke 
Valve Body 
Aluminum (Standard) 
Stainless Steel (Optional) 
Gas Fuel Filter (Conventional Units Only) 
10 Micron 
Offskid Coalescing Filter Module (SoLoNOx Units 
Only) 
 
Maximum Operating Pressure 
3447 kPag (500 psig) 
Maximum Flow 
122 m
3
/min (4300 ft
3
/min) 
Minimum/Maximum Operating 
Temperatures 
-29 to 100
°C (-20 to 212°F) 
Filtration Efficiency 
β0.3 > 200 per ISO 4572 
© 2008 Solar Turbines Incorporated. All rights reserved. 
TPS250GS/908 - Preliminary 
22