Turbomachinery Package Specification 
Titan 
250 Generator Set 
Figure 11.  Typical Lube Oil System 
8.1.7 
Lube Oil Vent Flame Arrestor 
The lube oil vent flame arrestor prevents an ignition source from entering the lube oil 
tank. The flame arrestor is loose shipped for offskid installation by others. 
8.1.8 
Lube Oil System Options 
Lube Oil Cooler 
An air-to-oil type cooler is available to provide oil cooling for the gas turbine and the 
driven equipment. The cooler is sized for specified heat loads and ambient temperatures 
and is designed for a 4.4°C (40°F) approach temperature. The cooler is loose shipped for 
offskid installation by others. 
Lube Oil Immersion Tank Heater 
The lube oil tank immersion heater ensures the lube oil tank temperature is adequate for 
starting in cold conditions. The tank heater also facilitates a short lube oil temperature 
warm up period after a cold start. Electrical supply contactors are not included. 
 
Table 6. 
Lubrication System Specifications 
Main Lube Oil Pump 
Pump Type 
Engine-Driven Rotary Screw 
Flow 
1999 lpm (528 gpm) 
Discharge Pressure 
690 kPag (100 psig), See Note (a) 
Pre/Post Lube Oil Pump 
Pump Type 
AC Motor-Driven Centrifugal 
Optional Motor Voltage Ratings 
380 VAC, 400 VAC, and 415 VAC (50 Hz) 
460 VAC and 575 VAC (60 Hz) 
Motor, Power 
7.45 kW (10 hp)  
Backup Lube Oil Pump 
Pump Type 
DC Motor-Driven Centrifugal 
Motor Voltage Rating 
120 VDC 
Motor, Power 
7.45 kW (10 hp) 
Lube Oil Cooler 
Lube Cooler Oil Volume (Per Cooler) 
Project Specific 
Design Heat Load (Per Cooler) 
Project Specific 
Design Oil Flow Rate (Per Cooler) 
Project Specific 
Air Flow Rate 
Project Specific, See Note (b) 
Maximum Ambient Temperature 
43°C (110°F) 
Maximum Design Lube Oil Cooler Outlet 
Temperature 
66°C (150°F) 
Maximum Lube Oil Cooler Design Pressure Drop 
173 kPag (25 psig), See Note (c) 
Minimum Lube Oil Cooler Design Pressure 
1 035 kPag (150 psig) 
Optional Motor Voltage Ratings 
380 VAC, 400 VAC, and 415 VAC (50 Hz) 
460 VAC and 575 AC (60 Hz) 
Optional Motor, Power 
7.5 kW (10 hp), 15 kW (20 hp), or 2 x 15 kW (20 
hp) 
Lube Oil Tank Immersion Heater, See Notes (d) and (e) 
Optional Voltage Ratings 
380 VAC, 400 VAC, and 415 VAC (50 Hz) 
460 VAC and 575 VAC (60 Hz) 
Power 
3-Phase VAC, 40 kW 
Minimum/Maximum Regulated Supply Pressure 
100 to 225 psig (689 to 1551 kPag) 
© 2008 Solar Turbines Incorporated. All rights reserved. 
TPS250GS/908 - Preliminary 
26