CAT Titan 250 Manual De Usuario

Descargar
Página de 81
Turbomachinery Package Specification 
Titan 
250 Generator Set 
15.1.7 Certification 
Certification is typically required to demonstrate offshore turbomachinery compliance with 
applicable rules for a fixed or mobile offshore installation. Solar can provide the 
necessary certification or assist the customer in obtaining certification. Involvement of 
one of the following certifying authorities is usually required: 
•  Det Norske Veritas (DNV) 
•  Bureau Veritas (BV) 
•  Lloyd’s Register (LR) 
•  American Bureau of Shipping (ABS) 
15.1.8  Deck Deflection Limits 
The package supporting deck structure must have sufficient stiffness to maintain 
alignment of the turbine and driven equipment under dynamic vessel motion. Table 13, 
lists the maximum allowable deflections measured between the furthest mounting points. 
With analysis, these limits may be extended through the use of gimbals or AVMs. 
15.1.9  Angular Displacement and Acceleration 
Table 15, Marinization Specifications, lists the maximum allowable angular displacement 
and acceleration limits for marine applications. The Basic Duty category is met by the 
standard package without any additional modification. Moderate Duty and Severe Duty 
categories require modification. 
15.1.10 Main and Auxiliary Service 
The information provided in this section does not apply to equipment used in “Main and 
Auxiliary Service”. If equipment is intended for this type of service, please contact Solar 
Turbines Incorporated for guidance to ensure the correct application and certification 
requirements are met. 
 
Table 13.  Marinization Specifications 
Supporting Deck Deflection Limits 
Hogging and Sagging 
0.3833 mm/m (0.0046 in/ft) 
Deck Twist 
0.0198°/m (0.006°/ft) 
Angular Displacement and Acceleration Limits 
Severe Duty 
 
Basic Duty 
Moderate 
Duty 
Parallel Perpendicular 
Maximum Permissible Angular Displacements 
Pitch / Period 
2° / 13 sec 
7.5° / 9 sec 
10° / 9 sec 
7.5° / 9 sec 
Dynamic: 
Roll / Period 
2° / 13 sec 
7.5° / 13 sec 
22.5° / 13 sec 
10° / 13 sec 
Trim 2° 5°  5° 
5° 
Static: 
List 2° 5°  15°  5° 
Maximum Permissible Accelerations 
Operating: 
± 0.1 g 
± 0.5 g 
± 1.0 g 
± 1.0 g 
Survival: 
± 0.5 g 
± 1.0 g 
± 1.5 g 
± 1.5 g 
 
© 2008 Solar Turbines Incorporated. All rights reserved. 