Turbomachinery Package Specification 
Titan 
250 Generator Set 
18.5 International 
Electrotechnical Commission Safety Assessment 
International Electrotechnical Commission (IEC) 61508 is an international standard that 
describes a standardized approach to Asses the functional safety of electric, electronic, 
and programmable electronic safety-related systems. This standard is based on a life-
cycle evaluation of system reliability and safety level determination. Safety integrity levels 
are categorized as SIL1, SIL2, SIL3, and SIL4. Levels are established by assessing the 
potential for personnel injury, equipment damage, and environmental damage. The 
installation site design and operating requirements will determine the applicable SIL level. 
Solar can provide reliability data on its equipment to assist customers in their overall 
safety assessments. 
18.6 Offshore 
Marine 
Applications 
For installations that require offshore marine certification, Solar conforms to the rules and 
standards established by certification authorities and/or customer specifications. 
Certification can be performed by one of the following authorities: 
•  Det Norske Veritas (DNV) 
•  American Bureau of Shipping (ABS) 
•  Lloyd’s Register (LR) of Shipping 
•  Bureau Veritas (BV) 
Solar can provide certification or provide supporting information to permit certification by 
another party. 
18.6.1  Det Norske Veritas Certification 
Det Norske Veritas (DNV) certification includes design verification and a manufacturing 
survey. DNV witnesses the fabrication and testing of engines and packages. Operations 
witnessed by DNV are defined in the inspection and test plan (ITP) that is prepared by 
Solar’s Quality department and approved by DNV at the beginning of a project. 
To eliminate redundant inspections, Solar has established a manufacturing survey 
arrangement (MSA) with DNV for a specific group of products. This MSA is based on a 
DNV audit of Solar's Quality System. The MSA authorizes Solar to carry out a specific 
level of inspections and tests without the presence of a DNV representative. 
18.6.2  American Bureau of Shipping 
The American Bureau of Shipping (ABS) performs design appraisals and inspections. 
Typically, ABS certification is performed according to ABS “Guide for Building and 
Classing Facilities on Offshore Installations,” 1991. ABS certification of Solar's gas 
turbines is based on compliance with the American Petroleum Institute (API) Standard 
616, with standard exceptions. 
18.6.3  Lloyd’s Register of Shipping 
Typically, Lloyd’s Register (LR) of Shipping performs design appraisals and 
manufacturing surveys. LR recognizes engine type approvals provided by DNV. LR’s test 
and inspection witness points are defined in the project Inspection and Test Plan (ITP). 
18.6.4 Bureau 
Veritas 
Bureau Veritas (BV) performs design appraisals and manufacturing surveys. Typically, 
BV certification is performed according to BV publication “Floating Production, Storage 
and Offloading Units Ch 10 NR456 April 1998.” Certification of Solar's gas turbines is 
based on compliance with the American Petroleum Institute (API) Standard 616, with 
specified exceptions. 
© 2008 Solar Turbines Incorporated. All rights reserved. 
TPS250GS/908 - Preliminary 
72