output use according to direction assignment from a control register in the PPI. Further, if a jumper is 
properly placed on the card, the tristate buffers may be enabled/disabled under program control. (See the 
Option Selection section to follow.)  
  
I/O wiring connections for the H card are via a 50-pin connector on the back plate of the card. Flat 
insulation-displacement ribbon cables can be used to connect these cards to termination panels and relay 
output cards. Also, the 50-pin connection provides compatibility with OPTO-22, Gordos, Potter & 
Brumfield and Western Reserve Controls module mounting racks. Fused +5 VDC power is available on 
the I/O connector at pin 49. The on-board fuse is rated at 0.5A at room temperature, and can be reset by 
cycling computer power, or by removing the load.  
  
I/O wiring connections for the D card are via a 37-pin D-sub connector on the back plate of the card. A 
37-pin D-sub solder cup mating connector, or flat insulation-displacement ribbon cable can be used to 
connect these cards to termination panels. The "D" version has a fused 5 volts available at connector pin 
20. The on-board fuse is rated at 0.5A, and can be reset the same as the H version.  