Delta Tau GEO PMAC Manual De Usuario

Descargar
Página de 117
Geo PMAC Drive User Manual 
Receiving and Unpacking 
15 
RECEIVING AND UNPACKING 
Delta Tau products are thoroughly tested at the factory and carefully packaged for shipment.  When the 
Geo Drive is received, do the following immediately. 
1.  Observe the condition of the shipping container and report any damage immediately to the 
commercial carrier that delivered the drive. 
2.  Remove the drive from the shipping container and remove all packing materials.  Check all shipping 
material for connector kits, documentation, diskettes, CD ROM, or other small pieces of equipment. 
Be aware that some connector kits and other equipment pieces may be quite small and can be 
accidentally discarded if care is not used when unpacking the equipment.  The container and packing 
materials may be retained for future shipment. 
3.  Verify that the part number of the drive received is the same as the part number listed on the purchase 
order. 
4.  Inspect the drive for external physical damage that may have been sustained during shipment and 
report any damage immediately to the commercial carrier that delivered the controller. 
5.  Electronic components in this amplifier are design-hardened to reduce static sensitivity.  However, 
use proper procedures when handling the equipment. 
6.  If the Geo Drive is to be stored for several weeks before use, be sure that it is stored in a location that 
conforms to published storage humidity and temperature specifications stated in this manual. 
Use of Equipment 
The following guidelines describe the restrictions for proper use of the Geo Drive: 
• 
The components built into electrical equipment or machines can be used only as integral components 
of such equipment. 
• 
The Geo Drives are to be used only on grounded three-phase industrial mains supply networks (TN-
system, TT-system with grounded neutral point). 
• 
The Geo Drives must not be operated on power supply networks without a ground or with an 
asymmetrical ground. 
• 
If the Geo Drives are used in residential areas, or in business or commercial premises, implement 
additional filter measures. 
• 
The Geo Drives may be operated only in a closed switchgear cabinet, taking into account the ambient 
conditions defined in the environmental specifications. 
Delta Tau guarantees the conformance of the Geo Drives with the standards for industrial areas stated in 
this manual, only if Delta Tau components (cables, controllers, etc.) are used. 
Geo PMAC drive is a combination of a PMAC2 controller and Geo Amplifier. So parallel with this 
manual the user needs to use the PMAC1/2 Software reference manual and the PMAC USERS manual. 
 
Note: 
Always download the latest manual revision from the Delta Tau website 
www.deltatau.com