Upgrade Guidelines
When upgrading to AMASS 5.4, please make note of the following upgrade guidelines.
Upgrade Instructions
 
1
For pre-installation instructions for a specific storage device, refer to the Accessing Storage Devices 
book.
2
Make sure the UNIX server has the required operating system patch levels.
Read the hard disk partitioning, space requirements, and guidelines on partitioning the cache in the 
“Getting Started” chapter in Installing AMASS.
3
Make sure the cache is empty by running the 
sysperf
 command and verifying that there are no dirty 
cache blocks.
Use 
killdaemons
 to inactivate AMASS, unmount the file system, and kill the AMASS daemons.
4
Upgrade the UNIX operating system, if required.
5
Shut down and power off the UNIX server where AMASS will be installed.
6
Fibre-Attached Devices: Connect the storage devices to the Fibre-Channel bus on the server. The 
Fibre-Channel driver must be one that maps World-Wide-Names to SCSI device names.
Network-Attached Devices: Connect the storage devices to the network.
The AMASS installation script retrieves and displays device addresses to aid you in the AMASS 
configuration process.
Operating 
System
Upgrade Guidelines
HP Tru64
To successfully install AMASS while using only part of a disk as the AMASS 
cache, you must first verify that the c partition of the disk has a file system 
type 
(
fstype) of unused. Second, you must verify that the user 
amass 
has read/write permission to the raw 
partition (for example, 
/dev/
rdisk/dsk2c
). You can get this permission by owning the file, belonging 
to a group that owns the file, or allowing access to all users of the file.
NOTE: If you do not perform these two verifications when attempting to 
start AMASS, you may get a message in the tac log that says the cache is 
invalid.
Note
Before upgrading your software and/or firmware, ADIC recommends that the 
AMASS database be backed up prior to performing the upgrade.
Note
The following tasks are presented as guidelines only because the actual steps 
are site-specific.
CAUTION
Run the 
sysdbchk
 utility to make sure there has been no database 
corruption.
Note
Make a full backup of the AMASS File System Database and Journal by 
running the 
amassbackup
 
-fv
 command.