BENDIX TCH-001-059 Prospecto

Descargar
Página de 2
Technical 
Bulletin
Bulletin No: 
Effective Date: 
Cancels: 
Page:  1 of 
Subject:
Bendix
®
 Tu-Flo
®
 550 pulley-driven, base-mounted compressors installed on certain Navistar
®
 V-8 engines 
may have a metal tag under the front-left mounting bolt, as shown below.  If the compressor with this metal 
tag is removed during engine service, please use the following procedure to re-install the compressor.    
(Note: this procedure does not apply if replacing the compressor with a different unit.)
BENDIX
®
 TU-FLO
®
 550 COMPRESSOR RE-INSTALLATION PROCEDURE
Be sure to follow all safety guidelines outlined in the Bendix
®
 Tu-Flo
®
 550 Compressor Service 
Data Sheet SD-01-337 before performing any maintenance procedures.
1.  Clean the bottom surface of the Tu-Flo
®
 550 compressor and top surface of the compressor mounting 
bracket. 
2.  Install a new gasket between the compressor and the compressor mounting bracket as specifi ed by 
the OEM.
TCH-001-059
10-20-2010
N/A
2
Pulley-Driven Compressor Mounting Position
Continued...
Bendix
® 
Tu-Flo
®
 550 Compressor
Front-left Mounting Hole
Pulley
Front-left Mounting Bolt
ATTN: PRIOR TO LOOSENING 
THE MOUNTING BOLTS, CALL 
1-800-AIR-BRAKE FOR INFO.  
WWW.BENDIX.COM  TCH-001-059
Metal Tag