Manual Document# 3PXCC4A3001 
 
33 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 
When setting the address (via the dipswitch) use the silkscreen on 
the printed circuit board. This silkscreen shows a “1” and a “0” to 
refer to the “on and “off” states that each switch is set to. Switch S1 
configures port one (labeled J1) and, on two port cards, switch S2 
configures port two (labeled J2). Least significant bit (LSB) and most 
significant bit (MSB) are labeled on the card. Table 1 shows the 
numerical weight and electrical connection of each switch position. 
Refer to Table 2 for COM port addresses. Table 3 shows frequently 
unused port addresses for applications when COM port addresses 
1-4 are already used. 
 
 
 
 
To install the 3PXCC4A card as COM1, 2, 3, or 4, follow the 
switch settings shown in Table 2. To install at another address, 
follow the switch settings shown in Table 3. 
 
Table 2.  Standard Port Addresses 
 
Table 1.  Address Switches 
Switch 
Position 7 6 5 4 3 2 1 
Bus Connection 
SA9 SA8  SA7 SA6 SA5  SA4 SA3 
Decimal Weight 
512 256  128 64 
  32  16  8 
Hex Weight 
200 
100 80 40 20  10 8 
 
 Base 
Hex 
Address 
Binary 
Equivalent 
Switch Settings 
MSB       LSB 
7654321 
COM1 
3F8 1111111000  1111111 
COM2 
2F8 1011111000  1011111 
COM3 
3E8 1111101000  1111101 
COM4 
2E8 1011101000  1011101