Brocade Communications Systems Brocade VDX 6710-54 Manual De Usuario

Descargar
Página de 12
Brocade VDX 6710-54 QuickStart Guide
9 of 12
Publication Number: 53-1002338-02
switch(config-Management-1/0)# ip address dhcp
Enabling and disabling Brocade VCS mode
Enable or disable a single switch for VCS™ mode as soon as passwords have been assigned and an IP address has 
been set. Enabling VCS mode is disruptive since a reboot is required once the mode has been enabled. Enabling or 
disabling VCS mode also causes the default configuration file for that mode to be applied. 
The basic configuration tasks include enabling or disabling VCS mode explicitly, setting VCS parameters, and 
applying the default configuration. If you disable VCS mode, you do not have to set the other parameters. For more 
details about enabling VCS mode and setting VCS parameters, please see the Brocade Network OS Administrator’s 
Guide
 and the Brocade Network OS Command Reference Guide.
Enabling VCS mode
Perform the following steps to enable VCS mode.
1. Log in to the switch using an account that has the admin role.
2. Enter the vcs enable command, including the RBridge parameter, as in the following example.
vcs rbridge-id 1 enable 
The switch reboots when you confirm that you want to enable VCS mode.
When the switch comes back up, if it is connected to other VCS-enabled switches, the negotiation protocols 
begin, determining which switch in the fabric is the principal switch and making sure that all domain IDs, and 
therefore RBridge IDs, are unique. Should the insistent domain ID not be unique, you can change it. Once the 
domain IDs are determined to be unique, they are equated to the RBridge IDs.
The switch with the lowest World Wide Name (WWN) becomes the principal switch, primarily for purposes of 
determining the uniqueness of the ID of the other switches in the fabric. The WWN is a unique identifier burned 
into the switch at the factory.
Another parameter that can be changed if necessary is the VCS ID. This identifies the VCS fabric of which the 
switch can be a part. By default, the VCS ID of every Brocade VDX 6710-54 is 1. Change the VCS ID if you need 
to create a new, separate VCS fabric.
3. If you need to change the VCS ID, enter the vcs vcs-id x command, where x is the new VCS ID number.
4. Enter the copy running-config startup-config command to apply the current running configuration to the startup 
configuration. This is important to capture any changes that have been made to the running configuration so 
that they will persist the next time the switch reboots in the same mode.
Disabling VCS mode
Perform the following steps to disable VCS mode.
1. Log in to the switch using an account that has the admin role.
2. Enter the no vcs enable command.
3. Reboot the switch.