SPECIFICATIONS 
 
Width: 25 ¼”  
Height: 29 ½” 
Depth: 24 ¼” 
Weight: 340 lbs. 
Flue size: 3” or 4” 
Hopper Capacity: Up to 40 lbs. 
(this can vary widely depending on pellet size, length, and 
diameter) 
EPA status: exempt 
Burn time: 1 lb. to 4 ½ lbs. per hour 
BTU range: 8,200 to 40,000 
Approved installations: mobile home, alcove, conventional 
 
PREPARATION 
 
Factory packaging must be removed, and some minor assembly 
work is required prior to installation. Access to the rear of the 
stove is necessary. 
 
NOTE: Normally, your dealer will perform these functions. 
 
CLEARANCES 
 
The Breckwell P4000 has been tested and listed for installation in 
residential, mobile home and alcove applications. 
FLOOR PROTECTION: Freestanding installations, minimum 
27 ¼” wide by 33 ¼” deep. The stove must be placed on a 
continuous (grouted joints) noncombustible material such as 
ceramic tile, cement board, brick, 3/8” millboard or equivalent, or 
other approved or listed material suited for floor protection.  
THE MATERIAL(S) USED MUST HAVE, OR COMBINE TO 
HAVE, A MINIMUM INSULATIVE RATING OF ‘R1’. 
NOTE: ceramic tile, or any tile, requires a continuous sheet 
beneath to prevent the possibility of embers falling through to the 
combustible floor if cracks or separation should occur in the 
finished surface, this would include floor protection for Built-in 
raised hearths. Check local codes for approved alternatives. 
Clearances are measured from the sides, back and face (door 
opening) or stove body (refer to fig. 3).  
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES 
IN THE INSTALLATION OF THIS UNIT. 