Bradford-White Corp 50T Prospecto

Descargar
Página de 2
Commercial Atmospheric Vent Gas Water Heater
NATURAL GAS AND LIQUID PROPANE GAS 
Light Duty Energy Saver Models 
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Thermal Efficiency
Model
Number
Approx.
Shipping
Weight
lbs.
G
Floor to
Space
Htg.
Outlet
in.
A
Floor to
Flue
Conn.
in.
H
Floor to
Water
Conn.
in.
B
Jacket
Dia.
in.
Capacity
Recovery at
100°F Rise*
50T-65FB-3N
65T-65FB-3N
75T-80B-3N
100T-88B-3N
U.S.
Gal.
Imp.
Gal.
Nat.
BTU/Hr.
Input
65,000
65,000
76,000
85,000
Nat.
U.S.
GPH
Nat.
Imp.
GPH
59
1
/
4
63
63
3
/
4
68
5
/
8
57
60
3
/
4
61
1
/
4
67
5
/
8
164
205
294
420
22
24
26
28
1
/
4
50
53
1
/
2
53
50
5
/
8
E
Floor to
Gas
Conn.
in.
13
12
3
/
16
16
1
/
2
15
5
/
8
13
1
/
2
13
1
/
2
17
3
/
4
17
5
/
8
F
Floor to
Space
Htg.
Return
in.
63
63
74
82
53
53
62
69
LP
U.S.
GPH
LP
Imp.
GPH
59
61
74
85
49
51
62
71
48
65
75
100
40
54
62
83
D
Floor to
T&P
Conn.
in.
50
53
1
/
2
53
59
5
/
16
C
Vent
Size
in.
4
4
4
4
Model
Number
Approx.
Shipping
Weight
kg.
G
Floor to
Space
Htg.
Outlet
mm.
A
Floor to
Flue
Conn.
mm.
H
Floor to
Water
Conn.
mm.
B
Jacket
Dia.
mm.
Capacity
Recovery at
56°C Rise*
50T-65FB-3N
65T-65FB-3N
75T-80B-3N
100T-88B-3N
Liters
Nat.
kW
Input
19.1
19.1
22.2
25.0
LP
BTU/Hr.
Input
61,000
63,000
76,000
88,000
LP
kW
Input
17.9
18.4
22.2
25.8
182
246
284
279
Nat.
Liters/
Hour
1550
1600
1619
1743
1448
1543
1556
1718
K
Depth
in.
26
28
30
32
1
/
4
K
Depth
mm.
660
711
762
819
74
93
133
191
559
609
660
718
1270
1359
1346
1286
E
Floor to
Gas
Conn.
mm.
330
309
419
397
343
342
451
448
F
Floor to
Space
Htg.
Return
mm.
238
238
280
310
LP
Liters/
Hour
223
231
280
322
D
Floor to
T&P
Conn.
mm.
1270
1359
1346
1506
C
Vent
Size
mm.
102
102
102
102
K
K
E
C
B
A
H
H
D&G
F
8"
B
**
E
F
TOP VIEW
TOP VIEW
T
C
A
D&G
** 75T=11"
** 100T=16"
All propane heaters are equipped with a cast iron burner. To order a propane heater remove the “B” designator and change suffix “N” to “X”.
For 5 year models, change suffix “3” to “5”.
*Based on manufacturers rated recovery efficiency.
Hand Hole Cleanout standard on 100T and optional on 75T models.
NSF kits available.
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). The 50T and 65T water connections are
3⁄4" NPT (19mm) on 8" (203mm) centers. The 75T water connections are 1" (25mm) NPT on 11" (279mm) centers and 100T water connections are 1
1
4
"
(32mm) NPT on 16" (406mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA),ANSI standard Z-21.10.1 and/or 10.3 and peak performance rated. This Water Heater
can be used as an Automatic Storage Heater, and an Automatic Circulating Tank Heater.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. 
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Printed in  U.S.A.
700-B 0807
©2007, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 
Fax 215-641-1670 / Technical Support 800-334-3393 
Fax 269-795-1089 
Warranty 800-531-2111 
Fax 269-795-1089
International: 
Telephone 215-641-9400 
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 905-238-0100 
Fax 905-238-0105 www.bradfordwhite.com
75T AND 100T MODELS
50T AND 65T MODELS