Bradford-White Corp ES-3000 Manual De Usuario

Descargar
Página de 6
ES-3000-1-S-10 3.0  120  25.0 
41 
10 
AWG
ES-3500-1-S-10 3.5  120  29.0 
48 
10 
AWG
ES-3500-4-S-10 3.5  240  14.6 
48 
14 
AWG
ES-4100-2-S-10 4.1  208  19.7 
56 
12 
AWG
ES-4100-5-S-10 4.1  277  14.8 
56 
14 
AWG
ES-5500-4-S-10 5.5  240  22.9 
75 
10 
AWG
Model
Number
kW
Rating
Voltage
AMPS
Temperature
Rise °F
0.5 GPM 
Recommended
Wire Size
Single Point (Single Phase)
Intregal 0.5 GPM flow control and faucet aerator provided.
Electric Instantaneous Water Heaters
3
8"
3
8"
OUTLET
FLOW
REGULATOR
REMOVABLE
FILTER
INTLET
Specifications:
Dimensions: 10
3
4
" x 5
1
4
" x 2
7
8
"
Weight: 3 lbs.
Materials:
Cover: ABS UL rated 94Vo.
Glass reinforced “UDEL†”
Heater Body and Ni Chrome Element
Color: White
Element: Replaceable cartridge insert
Pipe-Fittings: 3/8" compression at top
of unit.
Operating Pressure: Min 25 PSI,
Max 150 PSI.
5
1
4"
1
1
2"
3
4"
2
7
8"
10
3
4"
9
3
4"
OUTLET
INTLET
Specifications:
Dimensions: 10
3
4
" x 5
1
4
" x 2
7
8
"
Weight: 3 lbs.
Materials:
Cover: ABS UL rated 94Vo.
Glass reinforced “UDEL†” Heater Body and Ni
Chrome Element
Color: White
Standard temperature range 100°F-140°F.
Maintains accurate temperature control +/- 1°F 
Element: Replaceable cartridge insert
Pipe-Fittings: 1/2" compression at bottom of unit.
Operating Pressure: Min 25 PSI, Max 150 PSI.
EFT-7500-4-S-10 7.5 
240 
32.0 
— 
68  51
34
25
8 AWG
EFT-9500-4-S-10 9.5 
240 
40.0 
— 
86  65
43
32
8 AWG
Model
Number
kW
Rating
Voltage AMPS
Temperature Rise °F
0.5
GPM
0.75
GPM
1.0
GPM
1.5
GPM
2.0
GPM
Recommended
Wire Size
Thermostatic (Single Phase)
Turn on 0.5 GPM (up to 6.5kW)
Turn on 0.7 GPM (7.5 kW and up)
Max Flow 2.0 GPM
Refer to Voltage Identification Code Chart on page 5.
Note: Designed to comply with 0.5GPM handwashing code
target outlet temperature 105°F - 110°F. Please consult local
codes for electrical requirements. Additional voltages and
wattages are available. For more information please consult
factory.
Refer to Voltage Identification Code Chart on page 5.
Applications: Single Phase Only.
Dishwashers, Boosters (to 180°F). Schools, Hospitals, Nursing
Homes, Laboratories. Emergency Eye Wash Fountains. Single
and Multiple Handwash Stations.
SPEC OPTIONS:
EE
- Emergency Eyewash
S
- Sanitation Setting 180°F
FS
- Factory Set Temperature
(Ambient to 180°F)
ML
- Multiple Lavs (5.5 to 10kW)
Factory Set Temp 105°F. 
.5 GPM Turn On
Note: Designed to comply with 0.5GPM handwashing code target outlet
temperature 105°F - 110°F. Please consult local codes for electrical
requirements. Additional voltages and wattages are available. For more
information please consult factory.
Applications: Single Phase Only.
Shopping Malls, Schools, Stadiums, Public Hand Washing.
5
1
4"
1
1
2"
3
4"
2
7
8"
10
3
4"
9
3
4"
2
1
2"
ELECTRICAL
SUPPLY
2
Please specify your application
when you place your order.
Example: EFT-9500-4-S-10-S
(Dishwasher 180°F)