Leibherr USA Refrigerators and freezers for integrated use, door-on-door HRB 1110 HF 851 Manual De Usuario

Descargar
Página de 14
u
Check  5/16  ''  (8  mm)  presetting  (distance  between
appliance door and lower edge of crosspiece).
u
Raise the fitting aids
 Fig. 25 (30)
 to the unit door height.
Bottom stop angle ▲of fitting aid = upper edge of the unit
door to be fitted.
u
Unscrew  the  crosspiece
  Fig.  26  (31)
  by  undoing  the
locknuts
 Fig. 25 (32)
.
u
Hang  the  crosspiece
Fig.  26  (31)
  on  the
inside of the unit door
using  the  fitting  aids
Fig. 26 (30)
.
With 
a
23-5/8  ''  (600  mm)
wide cabinet:
u
To 
center 
the
crosspiece
Fig.  26  (31)
:  Mark  a
short  center  line  on
the unit door and put
the tip of the arrow on
the crosspiece on it.
Fig. 26 
w
Distances to the outer edges are the same to the right
and to the left.
With a 24 '' (609.6 mm) wide cabinet:
u
To align the crosspiece
 Fig. 26 (31)
: Mark a short center
line on the unit door and put the tip of the arrow on the
crosspiece  on  it.  Then  slide  the  crosspiece
Fig. 26 (31)
3/16 in. (5.5 mm) toward the hinge side.
For chipboard doors:
u
Secure the crosspiece
 Fig. 26 (31)
 with at least 6 screws
Fig. 26 (34)
.
For frame and panel doors:
u
Secure  the  crosspiece
  Fig.  26  (31)
  with  4  screws
Fig. 26 (34)
 at the edge.
u
Lift up the fitting aids
 Fig. 26 (30)
, turn around and insert
into the adjacent openings.
Fig. 27 
u
Attach the unit door on the adjusting bolts
 Fig. 27 (33)
 and
loosely screw the locknuts
 Fig. 27 (32)
 onto the adjusting
bolts.
u
Close the door.
u
Check the gap between the door and the surrounding unit
doors.
u
To laterally align the unit door: Move the unit door in the
X direction.
u
To align the unit door in the Y direction (height) and in
lateral inclination: Adjust the adjusting bolts
 Fig. 27 (33)
with a screwdriver.
w
The  unit  door  is  flush  and  in  alignment  with  the
surrounding unit fronts.
u
Tighten the locknuts
 Fig. 27 (32)
.
Fig. 28 
Ensure that both metal edges are flush, symbol //:
u
Drill pilot holes in the door of the unit taking care not to
go  all  the  way  through  the  panel  (you  could  make  a
preliminary hole with a bradawl).
u
Screw the appliance door to the unit door with screws
Fig. 28 (34)
 through the mounting brackets
 Fig. 28 (12)
.
Fig. 29 
u
To  align  the  unit  door  in  depth  Z:  Undo  top  screws
Fig. 29 (35)
,  bottom  hex  head  screws
 Fig. 29 (13)
,  then
move the door.
u
Do not allow the knobs and sealing lips
to  contact  the  door  -  important  for
functioning!
u
Set an air gap of 3/32 '' (2 mm) between
the door of the unit and the body of the
unit.
Fig. 30 
u
Check the fit of the door and re-adjust, if necessary.
u
Tighten all screws.
u
Tighten  the  locknuts
  Fig.  30  (32)
  with  the  ring  wrench
Fig.  30  (38)
,  while  counter-holding  the  adjusting  bolts
Fig. 30 (33)
 with a screwdriver.
Installation
12