4. Attach terminal lugs to line 1 (black), neutral (white), and line 2 
(red) wires. Loosen (do not remove) the setscrew on the front 
of the terminal lug and insert exposed wire end through 
bottom of terminal lugs. Securely tighten setscrew to torque 
as shown in the following Bare Wire Torque Specifications 
chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
5. Use a hex or Phillips screwdriver to connect the bare (green) 
ground wire to the range with the ground-link screw and 
ground-link section. The ground wire must be attached over 
the ground-link section and must not contact any other 
terminal.
6. Use 
³⁄₈" (1.0 cm) nut driver to connect the neutral (white) wire 
to the center terminal block post with one of the 10-32 hex 
nuts.
7. Connect line 2 (red) and line 1 (black) wires to the outer 
terminal block posts with 10-32 hex nuts.
8. Firmly tighten hex nuts.
IMPORTANT: Verify the tightness of the hex nuts.
9. Replace lower access cover.
A. Terminal lug
B. Setscrew
C. Line 2 (red) wire
D. Neutral (white) wire
E. Line 1 (black) wire
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 lbs-in. (4.0 N-m)
A
B
C
D
E
A. 10–32 hex nut
B. Line 2 (red) wire
C. Bare (green) ground wire
D. Ground-link screw
E. Neutral (white) wire
F. Line 1 (black) wire
G. Terminal lug
B
A
G
E
C
D
F