Countertop Requirements
,
WARNING: 
To reduce the risk of ignition of 
surrounding combustible materials, install at 
least 6" (150 mm) from both sidewalls and at 
least 2" (50 mm) from the rear wall.
The countertop must be level and horizontal. The 
stability of the countertop must be maintained after 
the cut-out has been made.
Technical Data
Total connected load electric: 0.8 VA
Installation Procedure
Prepare Installation Space
Create the cut-out in the countertop for one or several 
Vario appliances according to the installation diagram. 
The angle of of the cut surface to the countertop must 
be 90°.
After creating cut-out, remove shavings. Seal cut 
surfaces in a heat-resistant manner.
Some solid surface countertops require special 
installations. For example, heat reflective tape and 
rounded corners may be necessary. Contact the 
countertop manufacturer for instructions specific to 
your countertop.
Observe minimum distance between appliance 
underside and furniture parts of 
3
/
8
" (10 mm).
When installing multiple Vario appliances: 
Take into 
account space requirement for VV 200 connection 
strip between the appliances. Appliances can also be 
installed in individual cut-outs, bearing in mind a 
minimum distance between the appliances of 1
9
/
16
(40 mm).
Install Appliance
,
WARNING: 
Before you plug in an electrical cord 
or turn on power supply, make sure all controls 
are in the OFF position.
1
Make a mark exactly in the center of the cut-out. 
Fasten the mounting rails to the front and rear 
edge of the cut-out. The leading edges of the 
mounting rails must lie upon the countertop. The 
center marking of the mounting rails must 
correspond precisely with the center marking of 
the cut-out.
Note: 
For stone countertops, adhere the 
mounting rails with temperature-resistant dual-
component adhesive (metal on stone).
Gas
Natural Gas 
Type N
LPG (Propane) 
Type X
Pressure
6" water 
column 
(1.5 kPa)
10" water 
column 
(2.5 kPa)
A-burner full burn
94
74
A-burner low burn
49
36
B-burner full burn
128
87
B-burner low burn
58
42
Total connected load
16 000 BTU 
(4.7 kW)
16 000 BTU 
(4.7 kW)
Total consumption
0.45 m³/h
340 g/h
[
ƒ
 
 
¡
PP
¡
PP
PLQ


PP
PLQ PP
PLQ PP
PLQ PP



PP



PP