Gaggenau VG232214CA Instruccion De Instalación
![Gaggenau](https://files.manualsbrain.com/attachments/e11b1721784f5a70b2241df6162e1873b0047dc1/common/fit/150/50/907623d4f1c04dc47058b87de34aa5c17e5e17ba11fc088bd8a8ff8e8f30/brand_logo.png)
6
Countertop Requirements
,
WARNING:
To reduce the risk of ignition of
surrounding combustible materials, install at
least 6" (150 mm) from both sidewalls and at
least 2" (50 mm) from the rear wall.
least 6" (150 mm) from both sidewalls and at
least 2" (50 mm) from the rear wall.
The countertop must be level and horizontal. The
stability of the countertop must be maintained after
the cut-out has been made.
stability of the countertop must be maintained after
the cut-out has been made.
Technical Data
Total connected load electric: 0.8 VA
Installation Procedure
Prepare Installation Space
Create the cut-out in the countertop for one or several
Vario appliances according to the installation diagram.
The angle of of the cut surface to the countertop must
be 90°.
Vario appliances according to the installation diagram.
The angle of of the cut surface to the countertop must
be 90°.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat-resistant manner.
surfaces in a heat-resistant manner.
Some solid surface countertops require special
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
Observe minimum distance between appliance
underside and furniture parts of
underside and furniture parts of
3
/
8
" (10 mm).
When installing multiple Vario appliances:
Take into
account space requirement for VV 200 connection
strip between the appliances. Appliances can also be
installed in individual cut-outs, bearing in mind a
minimum distance between the appliances of 1
strip between the appliances. Appliances can also be
installed in individual cut-outs, bearing in mind a
minimum distance between the appliances of 1
9
/
16
"
(40 mm).
Install Appliance
,
WARNING:
Before you plug in an electrical cord
or turn on power supply, make sure all controls
are in the OFF position.
are in the OFF position.
1
Make a mark exactly in the center of the cut-out.
Fasten the mounting rails to the front and rear
edge of the cut-out. The leading edges of the
mounting rails must lie upon the countertop. The
center marking of the mounting rails must
correspond precisely with the center marking of
the cut-out.
Fasten the mounting rails to the front and rear
edge of the cut-out. The leading edges of the
mounting rails must lie upon the countertop. The
center marking of the mounting rails must
correspond precisely with the center marking of
the cut-out.
Note:
For stone countertops, adhere the
mounting rails with temperature-resistant dual-
component adhesive (metal on stone).
component adhesive (metal on stone).
Gas
Natural Gas
Type N
Type N
LPG (Propane)
Type X
Type X
Pressure
6" water
column
(1.5 kPa)
column
(1.5 kPa)
10" water
column
(2.5 kPa)
column
(2.5 kPa)
A-burner full burn
94
74
A-burner low burn
49
36
B-burner full burn
128
87
B-burner low burn
58
42
Total connected load
16 000 BTU
(4.7 kW)
(4.7 kW)
16 000 BTU
(4.7 kW)
(4.7 kW)
Total consumption
0.45 m³/h
340 g/h
[
¡
PP
¡
PP
PLQ
PP
PLQPP
PLQPP
PLQPP
PP
PP
PLQPP