GE PGP9830SJSS Hoja De Especificaciones
PGP9830SJ
GE Profile
™
Series 30" Downdraft Gas Cooktop
Specification Revised 4/15
*Note: A 5" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
Wall INstallatIoN: Wall installations
require 25" countertop depth. When cabinet
is flush against the wall, the fan housing can
is flush against the wall, the fan housing can
be rotated to the horizontal position for direct
venting through rear wall. Make a countertop
cutout in the range cabinet according to unit
cutout in the range cabinet according to unit
dimensions and installation type. Duct hole
is positioned in back of cabinet for through-
the-wall ducting.
PeNINsula or IslaNd INstallatIoN:
is positioned in back of cabinet for through-
the-wall ducting.
PeNINsula or IslaNd INstallatIoN:
For peninsula/islands a minimum 26"
countertop depth is suggested. Blower should
be in vertical position. Island or peninsula
countertop depth is suggested. Blower should
be in vertical position. Island or peninsula
cabinets may require adjustment in cutout
depth and/or location within the width
depth and/or location within the width
dimensions. Duct hole is positioned in bottom
of cabinet for island or peninsula installation.
slab INstallatIoN: For peninsula or
of cabinet for island or peninsula installation.
slab INstallatIoN: For peninsula or
island installation and rear wall ducting, 6"
PVC duct or locally approved piping should be
used if installing under a poured concrete slab.
INstallatIoN INformatIoN: Before
used if installing under a poured concrete slab.
INstallatIoN INformatIoN: Before
installing, consult installation instructions,
packed with product, for current dimensional
data.
Note: These cooktops are approved for
data.
Note: These cooktops are approved for
indoor use only.
40
Long
20
9
4
10-1/2
16
CL
Cabinet Dimensions (in inches)
21
7
⁄
8
ʺ
(21
15
⁄
16
ʺ SS)
20
1
⁄
2
ʺ
22ʺ
29
3
⁄
4
ʺ
2
3
⁄
16
ʺ
(2
1
⁄
4
ʺ SS)
28
3
⁄
4
ʺ
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 5" minimum spacing to adjacent side wall is required
(29
13
⁄
16
ʺ SS)
21
7
⁄
8
ʺ
(21
15
⁄
16
ʺ SS)
20
1
⁄
2
ʺ
22ʺ
29
3
⁄
4
ʺ
2
3
⁄
16
ʺ
(2
1
⁄
4
ʺ SS)
28
3
⁄
4
ʺ
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 5" minimum spacing to adjacent side wall is required
(29
13
⁄
16
ʺ SS)
dImeNsIoNs aNd INstallatIoN INformatIoN
For answers to your Monogram,
®
GE Profile
™
or GE
®
appliance questions, visit our website
at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories