CRU DE100, Complete Assembly, 68-pin, U160 6506-1000-0000 Prospecto

Los códigos de productos
6506-1000-0000
Descargar
Página de 2
Rugged, Reliable, Mobile, Secure
TM
1-800-260-9800
www.CRU-DataPort.com
Typical 2MM Drive ID Pin Configuration
Figure below illustrates a typical SCSI ID select connection to a drive with 2mm 
ID select pins. The wires on the wire harness connect to the positive pin (or 
signal pins) on the disk drive. In some cases, the drive manufacturer will label 
the signal pins as Pin 1, 3, 5, 7, (instead of 0, 1, 2, 3 as shown in figure below). 
Also, in some cases, the even-numbered Pins 2, 4, 6 are used for Ground.
Attach the ID select cable to the drive using the 2mm connectors. Align the 
“ID0” pin with the black wire. Attach the 1.25mm connector on the other 
end of the ID select cable to the 1.25mm connector (J3B) provided on the 
signal distribution board, located inside the carrier. Refer to the manufactur-
er’s documentation to disable termination on the drive.
Figure 3: Receiving Frame Motherboard (rear view)
Figure 4: Typical SCSI ID Select Connections (2mm Drive Pins)
Selecting the Unit ID Number: Use the alignment tool (provided) to select 
the ID number of the disk drive.
NOTE: The lock on the Data Express receiving frame functions as a lock and a 
DC power switch for the carrier unit. The lock MUST be engaged (turned coun-
terclockwise) in order to supply power to the carrier and installed drive unit.
Limited Product Warranty 
CRU-DataPort (CRU) warrants the Data Express DE100 to be free of significant de-
fects in material and workmanship for a period of five years from the original date of 
purchase. CRU’s warranty is nontransferable and is limited to the original purchaser.
Limitation of Liability
The warranties set forth in this agreement replace all other warranties. CRU expressly 
disclaims all other warranties, including but not limited to, the implied warranties of 
merchantability and fitness for a particular purpose and non-infringement of third-party 
rights with respect to the documentation and hardware. No CRU dealer, agent or em-
ployee is authorized to make any modification, extension, or addition to this warranty. 
In no event will CRU or its suppliers be liable for any costs of procurement of substitute 
products or services, lost profits, loss of information or data, computer malfunction, or 
any other special, indirect, consequential, or incidental damages arising in any way out 
of the sale of, use of, or inability to use any CRU product or service, even if CRU has 
been advised of the possibility of such damages. In no case shall CRU’s liability exceed 
the actual money paid for the products at issue. CRU reserves the right to make modi-
fications and additions to this product without notice or taking on additional liability. 
Certification
EMI Standard:  
FCC Part 15 Class B, CE
EMC Standard:  
EN55022, EN55024
FCC Certification
This device has been tested and found to comply with the limits for a Class B 
digital device, pursuant to Part 15 of the FCC rules. Operation is subject to the 
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received; including interference that  
 
      may cause undesired operation.
Register your product at www.CRU-DataPort.com.
      A7-100-0008  Rev. 1.1
Figure 5: Unit ID Select Switch Location