TECHNICAL DATA
Standard Water Flow  2 GPM at 22,5 PSI
Maximum Water Flow 2.2 GPM at 150 PSI
Recommended Pressure Range 22,5 PSI
Complies with NSF61, AB1953, and ASME A112.18.1-2005/CSA B 125.1-2005
Requirements
NOTE:
Call us immediatly if you see inconsistencies.
(1- 800-626-5771)
or visit
www.frankeksd.com
info.fks@franke.com
CONTENTS IN BOX
1
Faucet assembly
2 Rubber 
washer
3
Mounting Shank
4
Rubber washer
5
Plastic flange
6
Shaped washer
7 Fixing 
plate
8
Fixing nut
9
Flexible supply hoses
10 Nipples (not included in US models)
11 Key for aerator
INSTALLATION INSTRUCTIONS
1. Remove all contents from the package and check for completeness.
2. Flush pipe work to ensure it is free from debris.
3. Turn off water supply.
4. Remove faucet and hardware from its protective packaging.
Faucet comes assembled.
5. Connect the 2 flexible supply hoses (9) - red hot water, blue cold
water - to the body of the faucet (1).
6. Cut a mounting hole 1 3/8 diameter (35mm) in the desired position in
counter  top or sink (if one isn’t available).
7. Place the rubber washer (2) over the hole.
ATTENTION: The washer should be sitting between the countertop and
faucet base.
DO NOT use putty or other sealant at this location.
NOTES
Solid surface installation: The countertop mounting surface needs to
be flat and free of debris otherwise the faucet may not sit properly.
For tile installations, avoid installing faucet near or on top of grout lines.
This may cause a weak joint between the faucet and the counter and
could cause leaks.
8. Install the monting hardware to the base of the faucet body in
the following order - rubber washer (4); plastic flange (5) shaped
washer (6) and the fixing plate (7) as illustrated.
9 .Tighten the body down installing Fixing Nut (8) to the Mounting
Shank (3).
10. Connect the flexible supply hoses to the water supply in the house
and turn on the faucet. Ensure everything is functioning properly and
check/ test for leak.
2
1
3
4
5
6
7
8
9