3
Check that O-ring is correctly positioned in new 
full-burn nozzle for inner circular burner. Push 
nozzle onto burner pipe. Screw new main nozzle 
for outer circular burner all the way into nozzle 
fitting.
4
Put on nozzle fitting and burner pipes. Put on 
securing clips.
5
Set air-regulating tube to correct dimension after 
loosening the screw (see nozzle table). Tighten 
screw again.
6
Put stovetop in place and screw it tight. Put 
burner par ts and pan suppor t in place, 
positioning them correctly.
If it should be necessary to correct the low -setting 
nozzle as the result of deviating gas types and 
pressure, the flow rate can be increased by turning to 
the left.
These burners do not require the primar y air to be 
adjusted.
Checking functions after the conversion:
 
The flames are adjusted correctly if no yellow tips are 
visible. They must not go out when switching over 
swif tly from the high to the low setting.
Note: 
Stick the adhesive label included with the 
nozzle set over the rating plate of the appliance to 
document the changeover to a dif ferent gas type.
Service
Contact our Ser vice department if your appliance 
needs repair. Our central Customer Ser vice Center 
(see below) will also be happy to supply you with 
details on a center close to you.
When you contact our Customer Ser vice, please have 
the E number and the FD number for your appliance 
available. You can find the product data plate with 
these numbers on the underside of the appliance.
Questions? Please contact us. We look for ward to 
hearing from you!
877-4-GAGGENAU
 
www.gaggenau-usa.com
5551 McFadden Avenue 
Huntington Beach, CA 92649
&
'