Step 7: Backguard Installation
WARNING
To avoid possible burn or fire hazard, a 
backguard designed specifically for this 
range must be installed whenever the 
range is used.
DO NOT attempt to install a Thermador 
series backguard, which has air holes in 
the back panel to supply (only) one cooling 
fan. [See Figure 16]
See Chart C for the correct size of Backguard Kit to match 
the range.
The backguard must be attached before sliding the 
range into the final, installed position. A Low Back or 
Pot-and-Pan Shelf must be installed when there is less 
than 12” clearance from a combustible back wall and 
the back of the range above the cooking surface. 
A Flush Island Trim is available for covering the 
backguard area of the range for island installations; 
however, the Flush Island Trim can only be used where 
there is a minimum of 12” horizontal clearance 
between a combustible back wall and the back of the 
range.
The backguard is inserted inside the guide channels on 
the back of the range, as shown in Figure 16. (Remove 
the griddle assembly for sufficient installation clearance 
on models with griddle.) Using a T-20 size Torx driver, 
fasten the backguard with four (4) Torx-head screws to 
the range side panels.
The Pot-and-Pan Shelf models require pre-assembly of 
the top panel to the shell using nine (9) of the enclosed 
Torx-head screws. For sufficient load strength, YOU 
MUST attach two (2) screws through the back corners 
of the top down into the shell.
To secure the front of the back guard, install three (3) 
of the Torx head screws through the lower front panel 
of the backguard, into the flange at the back of the 
range’s cooktop.
The Pot-and-Pan Shelf models provide a shelf above 
the cooktop to keep foods hot or store cooking pans. 
OBSERVE CAUTIONS CONCERNING ITEMS 
PLACED ON TOP OF THE SHELF.
CAUTION
The Pot and Pan Shelf can get very hot!
DO NOT place the following items on top of the 
Pot and Pan Shelf:
plastics or containers that can melt
flammable items
a total load over 30 pounds (13.6kg)
 Figure 15:  Secure Neutral Wire
 Figure 16: Backguard Positioning
Ground Wire
L1 Black
L2 Red
Front of Range
The back panel of backguard is positioned inside 
these two guide channels on the back of the range.