Installation instructions
 
for your new
  Before you begin—Read these instructions completely and carefully.
  IMPORTANT—OBSERVE ALL GOVERNING CODES AND ORDINANCES. 
  Note to Installer— Be sure to leave these instructions with the  
Consumer. 
  Note to Consumer— Keep these instructions with your Built-In  
Air Conditioner Owner’s Manual and Installation 
Instructions for future reference.
1
CRITICAL DIMENSIONS
NOTE: 
Care should be taken in location of electrical 
supply entry in relationship to wall sleeve to ensure 
access to power once the unit is installed.
 
 
RECOMMENDED
 DIMENSIONS 
INSTALLATION CLEARANCE
 
A
Top of case to finished ceiling—3″ min.
 
B
Projection of case into room—1/4″ min. 
 
 
If more than 6″ of the case projects
 
 
into the room, other support is    
 
 
recommended.
 
C
Projection of case to outside—1/4″ min.
 
D 
Height above finished floor or top of  
carpet—0″ min. 
 
E
Left/Right side of case to adjacent
wall—2″ min.
31-61545 GE 09/28/09
INSTALL CASE LEVEL IN ALL DIRECTIONS
NOTE:
 Handle the case carefully.
CASE LOCATION
As a general rule the air conditioner should  
be located in an outside wall to ensure proper 
distribution of conditioned air. It should be located  
in a portion of the wall where there is no electrical 
wiring or plumbing, and where there are no 
obstructions immediately inside or outside.
Ceiling
“A”
“B”
“C”
Roomside
Outside wall
“D”
Finished floor or top of carpet
Outside wall
“E”
“E”
Top of case
Printed in the United States
RAB46, RAB47  
and RAB48 Room  
Air Conditioner Case  
for AJ Series Built-In 
Models