Zephyr CCAE30ASX Manual

Descargar
Página de 22
T
roubleshooting
19
TROUBLESHOOTING PROCEDURES FOR CACHE
Issue
Cause
What to do
After installation, 
the unit doesn’t 
work.
1. The power source is not turned ON.
1. Make sure the circuit breaker and the unit’s 
power is ON.
2. The power line and the cable locking connector 
is not connecting properly.
2. Check the power connection with the unit is 
connected properly.
3. The switch board and control board wirings are 
disconnected.
3. Make sure the wirings between the switch 
board and control board are connected 
properly.
4. Wire harness from external or internal blower 
might be disconnected.
4. Make sure the wires are connected to the 
control board box
5. The switch board or control board is defective.
5. Change the switch board or control board.
Light works, 
but motor is not 
turning.
1. The motor is defective, possibly seized.
1. Change the motor.
2. The thermally protected system detects if the 
motor is too hot to operate and shuts the motor 
down.
2. The motor will function properly after the 
thermally protected system cool down.
3. Damaged capacitor.
3. Change the capacitor.
The unit is 
vibrating.
1. The motor is not secure in place.
1. Tighten the motor in place.
2. Damaged blower wheel/makes noise.
2. Change the motor.
3. The hood is not secured in place.
3. Check the installation of the hood.
The motor is 
working, but the 
lights are not.
1. Defective halogen bulb.
1. Change the halogen bulb.
2. The light bulb is loose.
2. Tighten the light bulb.
The hood is 
not venting out 
properly.
1. The hood might be hanging to high from the 
cook top.
1. Adjust the distance between the cook top and 
WKHERWWRPRIWKHKRRGZLWKLQ´DQG´
range.
2. The wind from the opened windows or opened 
doors in the surrounding area are affecting the 
ventilation of the hood.
2. Close all the windows and doors to eliminate 
WKHRXWVLGHZLQGÀRZ
3. Blocking in the duct opening or ductwork.
3. Remove all the blocking from the duct work or 
duct opening.
4. There are too many turns within the ducting.
4. Limit number of turns and/or increase duct 
size.
5. Using the wrong size of ducting.
 &KDQJHWKHGXFWLQJWRDWOHDVW´RUKLJKHU
IRUWKHLQWHUQDOEORZHUDQG´RUKLJKHUIRUWKH
external blower.
Filter is vibrating.
 %DIÀH¿OWHULVORRVH
 5HPRYH¿OWHUDQGUHLQVWDOOLWRUFKDQJHWKH
EDIÀH¿OWHU
After hood has 
been installed 
for a period of 
time, it stopped 
working.
1. Control board needs to be reset.
1. Turn circuit breaker which controls the hood 
off for at least 15 minutes. Turn it back on and 
WKLVVKRXOG¿[WKHSUREOHP
2. Defective control board.
2. Replace control board.