Thermador PRG366JG Instruccion De Instalación

Descargar
Página de 90
English 7
Gas and Electric Supply Zones:
 
NOTICE:
--
If not already present, install gas shut-off valve in an 
easily accessible location. 
--
Make sure all users know where and how to shut off 
the gas supply to the range.
--
Any opening in the wall behind the appliance and any 
opening in the floor under the appliance must be 
sealed.
The gas ranges may be connected to the power supply 
with power cord (supplied with the range) or by hard-wiring 
to the power supply. It is the responsibility of the installer to 
provide the proper wiring components (cord or conduit and 
wires) and complete the gas connection as dictated by 
local codes and ordinances, and/or the National Electric 
Code. The units must be properly grounded. Refer to “Step 
7: Electrical Requirements, Connection & Grounding” on 
page 15
 for details. 
The range must be connected only to the type of gas 
for which it is certified.
 If the range is to be connected to 
propane gas, ensure that the propane gas supply tank is 
equipped with its own high pressure regulator in addition to 
the pressure regulator supplied with the range (see “Step 6: 
Gas Requirements and Hookup” on page 14
).
Note:
The range is designed for nearly-flush installation to the 
back wall. For a successful installation, it may be 
necessary to reposition the gas-supply line and electrical 
cord as the range is pushed back to its final position.
--
SUGGESTION: This may be accomplished by carefully 
pulling on a rope or twine looped around the gas or 
electrical supply line as the range is pushed back into 
its final installed position. 
 F
IGURE 
4: G
AS 
& E
LECTRICAL 
S
UPPLY 
L
OCATIONS
A
B
C
D
10” (254mm)
2” 
36” Model (913mm) 
 
 
3” (76mm)
48” Model (1219mm)
Model
A
B
C
D
36” (913mm)
9
” (232mm)
7
” (187mm)
7
” (187mm)
9
” (232mm)
48” (1219mm)
23
” (587mm)
7” (178mm)
7” (587mm)
7
” (200mm)
Gas Supply
Zone
Electric Supply
Zone
(51mm)