Introduction
This manual is designed to provide product, performance
and application information to our customers and their
architects and engineers for use in selection and design of a
zonal comfort control system utilizing GE Zoneline
®
Packaged Terminal Air Conditioners (PTAC) and
Packaged Terminal Heat Pumps (PTHP). GE Zoneline
®
PTACs and PTHPs are self-contained units designed for
through-the-wall installations in hotels, motels, apartments,
hospitals, nursing homes and add-on rooms.
Zoneline models provide individual room or zone control in
both cooling and heating operation. There is a model for
practically every application, ranging in cooling capacities
from 7,000 to 15,000 BTUH and heating capacities from
6,400 to 14,500 BTUH in heat pump operation.  A choice of
electric resistance heat is available ranging from 2.55 KW to
5.0 KW on 230 volt units and from 1.7 KW to 5.0 KW on 265
volt units.
The Zoneline offers a two tier lineup; the Deluxe Line -  the
2200 Series with electric resistance heat, the Dry Air 25
Models with enhanced dehumidification for hot and humid
climates and the 3200 Series heat pump; the Premium Line -
5200 Series heat pump.
The Deluxe Line units use standard microprocessor controls
with a two fan motor design. Zoneline 2200 Series
(including the Dry Air 25 Models) Packaged Terminal Air
Conditioners and 3200 Series Packaged Terminal Heat
Pumps offer as standard many of the features found on
competitive units only as added cost options. Features such
as Freeze Sentinel
TM
, Central Desk Control compatibility*,
Low Voltage Remote Thermostat Control compatibility*,
compressor restart protection, random restart after power
failure, mechanical temperature limiting, are standard on
the Deluxe Line.  The Deluxe Line also provides some
features not found, even as options, on some competitive
units. Features such as Indoor Coil Frost Control to enable
the unit to operate in the cooling mode under low outdoor
ambient conditions, and a two-stage thermostat on the 3200
Series Heat Pump unit helps maintain a comfortable room
for the occupant while saving energy for the property owner.
The Deluxe Line units also offer cooling with electric heat
and heat pump efficiencies that make them an outstanding
value; Deluxe represented by low operating cost - Deluxe
represented by the standard features - and Deluxe
represented by the competitive initial cost.
The Premium Line units are highly featured micro-processor
controlled and have separate indoor and outdoor fan
motors. The 5200 Series Packaged Terminal Heat Pumps
offer as standard all the features found on the Deluxe Line
units - Freeze Sentinel
TM
, Central Desk Control
compatibility*, Low Voltage Remote Thermostat Control
compatibility*, and Indoor Coil Frost Control - plus the
added features made possible through the use of electronic
controls; features such as automatic fan speed control,
staged heating, electronic temperature limiting, high
ambient heat pump operation, and unit diagnostics. The
5200 Series Heat Pump units also have an exclusive feature
in PTHP units - Selectable Full Time or On Demand
Simultaneous  Operation of Heat Pump and Supplemental
Resistance Heat - which provides the most advanced heat
pump operation to assure room occupant comfort while
providing the energy savings of a heat pump. The active
demand reverse cycle defrost system is designed to melt
accumulated frost on the outdoor coil and allow the unit to
resume cost efficient heat pump operation.
Advantages of the GE Zoneline
®
 System:
• Flexible Application
• May be installed flush to finished floor to 3" from
the ceiling
• 7,000 to 15,000 BTUH units in same physical size
• 2200 and 3200 Series may be ducted to condition
more than one room
• Compatible with Class 2 remote thermostat control*
• Compatible with 2 wire CDC or many Energy
Management systems*
• Economical Installation
• No ductwork necessary
• No mechanical equipment rooms or pipes required
for heating/cooling units
• Replacement units fit existing 42" wide by 16" high
wall cases
• Quiet Operation
• Indoor double cut-off scroll: two fan motor 2200 and
3200 Series units
• Indoor cross-flow blower: 2 fan motor 5200 Series
units
• Energy-Saving Operation
• Units in unoccupied areas may be turned off
• Designed for efficient cooling operation -  EERs from
9.6 to 12.0
• Efficient heat pump units - COPs from 3.1 to 3.5
• Extended heat pump operation without sacrificing
room comfort
• Ease of Maintenance
• Permanently lubricated fan motors
• Upfront lift out filters
• Slide out chassis for easy access if service is required
• Heat Pump Operation (Defrost Termination)
After the heat pump models have been exposed to a
low outdoor temperature and operating in the
switchover operational mode, the 3200 series returns to
heat pump operation at 36°F outdoor coil temperature,
and the 5200 series returns to heat pump operation at
32°F outdoor air temperature.
NOTE: All 2200 Series features mentioned in this manual
include the Dry Air 25 models.
*Optional Interface Module (RAKOIM)is required for Central
  Desk Control or Remote Thermostat Control adaptation.