8
2200 Series
Dry Air 25
Models
COOLING WITH RESISTANCE HEAT
High Efficiency (EER 9.6 to 11.6) - Standard Microprocessor
Controls, Fan cycle switch, Fan only setting and Concealed
manual vent control. All models are equipped with Freeze
Sentinel
TM
, mechanical temperature limiting and low
voltage (24v) DC power supply for 2 wire Central Desk
Control* systems. Units are easily convertible for use with
remote thermostat control.*
3200 Series
COOLING, HEAT PUMP
WITH RESISTANCE HEAT BACKUP
High Efficiency (EER 9.6 to 11.6; COP 3.1 to 3.5) Standard
Microprocessor Controlled Heat Pump models. 3200 Series
includes all 2200 Series features, plus heat pump operation.
Heat Pump operates to outdoor temperatures as low as 25°F.
(9°F outdoor coil temp) depending upon outdoor humidity
conditions and/or the balance point of the system. The unit
automatically switches to Resistance Heat if heat pump is
unable to maintain room conditions. Utilizes passive air defrost
system.  Resumes Heat Pump operation when
outdoor coil reaches 36°F. “Internal Condensate Removal”
(ICR) system is available as an option. ICR minimizes the need
for expensive internal or external drain systems to remove
condensate generated during heat pump operation.
5200 Series
COOLING, HEAT PUMP
WITH RESISTANCE HEAT BACKUP
Full Featured, High Efficiency (EER 10.0 to 12.0; COP 3.1 to
3.5),  Highly Featured Microprocessor Controlled Heat
Pumps. 5200 Series features include Freeze Sentinel
TM
,
Automatic Fan Speed Control, Staged Heating, Universal
Heater, UPC Power Connection, and 7-step Electronic
Temperature Limiting. All 5200 Series models are adaptable
to 2 wire Central Desk Control* systems. Units are also easily
convertible for use with remote thermostat control.* The
Heat Pump operates to outdoor temperatures as low as 25°F.
After a low outdoor temperature (less than 25°F) the unit
resumes heat pump operation when outdoor air
temperature reaches 32°F.
If heat pump is unable to maintain selected room conditions
when outdoor temperatures are below 46°F., the unit will
automatically phase-in partial resistance heat simultaneously
with heat pump operation before switchover to full resistance
heat. 5200 Series features an active demand reverse cycle
defrost system. “Internal Condensate Removal” (ICR)
system is available as an option. ICR minimizes the need for
expensive internal or external drain systems to remove
condensate generated during heat pump operation.
*(Requires “Optional Interface Module” (RAKOIM) for Central
  Desk Control or Remote Thermostat Control operation.)
Zoneline
®
 Chassis Nomenclature
 
   The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features
included on the unit. When specifying or ordering the Zoneline chassis the use of this nomenclature will assure receiving the correct unit.
Example
A      Z      5      2      H      1      2      D      A      D
Zoneline
®
 Packaged Terminal Chassis
      Chassis Series
22 - Deluxe Line Cool/Electric Heat
32 - Deluxe Line Heat Pump
52 - Premium Line Heat Pump
     Unit Type
E - Cooling with Electric Resistance Heat
H - Heat Pump with Electric Resistance Heat
    Special Features
B - Base Unit
C - Corrosion Treated
D - Internal Condensate Removal
      (ICR) System (Heat Pump Models Only)
P - Dry Air 25
5200 Universal Power Connection
  (see Premium Series Models - see page 53)
2200, Dry Air 25 & 3200 Numeric Designator
of Heater Size
 (see Deluxe Series Models - see Page 52)
     Voltage/Frequency
D - 230/208 Volt    60 Hz           E - 265 Volt    60 Hz
     Nominal Cooling Capacity
07 - 7,000 BTUH Cooling    12 - 12,000 BTUH Cooling
09 - 9,000 BTUH Cooling    15 - 15,000 BTUH Cooling