Friedrich S36YF Instruccion De Instalación

Descargar
Página de 8
Error code
Error contents
Outdoor signal abnormal
Excessive outdoor pressure (permanent stop)
Compressor temperature sensor
Pressure switch error
IPM error
CT error
Active filter module (AFM) error
Compressor does not operate
Outdoor unit fan error
Communication error
(inverter       multicontroller)
2 way valve sensor error
Expansion valve error
Connection indoor unit error
13
14
15
16
17
18
19
1A
1b
1c
1d
1E
1F
Indoor unit No. 
0
Indoor unit No. 
1
Indoor unit No. 
2
Indoor unit No. 
3
Remote
controller
wire
Remote
controller
(2) Rotary switch setting (indoor unit)
Set the unit number of each indoor unit using the rotary switch on the
indoor unit circuit board.
The rotary switch is normally set to 0.
(3) DIP switch setting (remote controller)
Change DIP switch 1 No. 3 on the remote controller from OFF to ON.
Indoor unit
Rotary Switch
Remote controller
DIP Switch 1
2. DUAL REMOTE CONTROLLERS (OPTIONAL)
Two separate remote controllers can be used to operate the indoor units.
(1) Wiring method (indoor unit to remote controller)
(2) DIP switch setting (remote controller)
Set the remote controller DIP switch 1 No. 1 and 2 according to the
following table.
Number of
remote
controllers
Master unit
1 (Normal)
2 (Dual)
ON
OFF
OFF
OFF
DIP-SW 1 No. 1 DIP-SW 1 No. 2
Remote controller
DIP Switch 1
Number of
remote
controllers
Slave unit
1 (Normal)
2 (Dual)
ON
ON
DIP-SW 1 No. 1 DIP-SW 1 No. 2
SW3
1  2  3
1  2  3
1  2  3
ON
OFF
1
2
3
4
5
6
ON
1  2  3
1  2  3
1  2  3
1  2  3
1  2  3
ON
OFF
1
2
3
4
5
6
1. GROUP CONTROL SYSTEM
A number of indoor units can be operated at the same time using a single
remote controller.
(1) Wiring method (indoor unit to remote controller)
SPECIAL INSTALLATION METHODS
 CAUTION
When setting the rotary switch and DIP switches, do
not touch any other parts on the circuit board directly
with your bare hands.
Be sure to turn off the main power.
Remote
controller
wire
Indoor unit
Master
unit
Slave
 unit
Remote
controller
PART NO. 9364488028
NO.
SW state
Detail
OFF
ON
1
Invalidity
Validity
★ Auto restart setting
2
★ Temperature correction
3
★ setting
1
Wireless
Wired
Remote controller setting
2
Air flow setting
3
DIP-Switch 1
 Indoor unit
 Remote controller
[DIP-SWITCH SETTING]
DIP-Switch 4
3. AUTO RESTART
• When the air conditioner power was temporarily turned off by a power
failure etc., it restarts automatically after the power recovers.
(Operated by setting before the power failure)
The auto restart function can be
canceled.
(1) DIP switch setting (indoor unit)
Change the DIP switch (SW1-1)
on the indoor unit circuit board
from ON to OFF. The auto restart
function will be canceled.
Indoor unit
O
F
F
1
2
3
OFF
SW1
O
F
F
1
2
3
SW4
DIP Switch
(
★: Factory setting)
ON
Multiple units
Cooling only model
★ Validity
Validity
Invalidity
Invalidity
Invalidity
Invalidity
Detail
Dual remote controller setting
Group control setting
Model setting
AUTO changeover setting
Memory Backup setting
THERMO SENSOR button setting
ENERGY SAVE button setting
Horizontal airflow direction and swing button setting
Vertical airflow direction and swing button setting
Cannot be used.
Cannot be used.
No.
1
2
3
4
5
6
1
2
3
4
5
6
OFF

★ One unit
★ Heat & cool model
Invalidity
★ Invalidity
★ Validity
★ Validity
★ Validity
★ Validity
★ Fixed at OFF
★ Fixed at OFF
SW state
DIP-
switch 1
DIP-
switch 2